Hakko FA-430. Filtergerät

Lieferzeit
2-3 Tage
  • HEPA filter (High Efficiency Particulate Air Filter)
  • Filters out 99.97% of particles greater than 0.3μm
  • Recommended for quiet laboratory and office
Artikel
HK-FA-430
Sonderpreis 857,24 € 739,00 € Regulärer Preis 912,92 €
 
Hakko
HOCHWERTIGE QUALITÄTSPRODUKTE
Bei uns finden Sie nur branchenführende Produkte der renommiertesten Hersteller.

ZUVERLÄSSIGE SUPPORT
Mit unserem kompetenten und freundlichen Team sind wir für Sie und Ihr Unternehmen da.

SCHNELLE LIEFERZEITEN
Wir bieten ein komplettes Spektrum an Zustelloptionen, das auch Ihren Versandanforderungen gerecht wird.

SECURE CHECKOUT
Wir benutzen volle SSL-Verschlüsselung zum Schutz Ihrer vertraulichen Informationen online.

Employing HEPA* filter! (High Efficiency Particulate Air filter)
Suitable for soldering in laboratory or office environment

HEPA filter captures 99.97% of particles greater than 0.3μm

FA-430 provides excellent filtering efficiency, 99.97% of particles greater than 0.3μm, by HEPA filter.


Filter replacement notification function ensures excellent trapping efficiency can be maintained at all times

No matter how sophisticated a fume extractor is, if the filter is not replaced at the right time, it will not be able to give maximum performance. The HAKKO FA-430 detects the number of fan rotation and notifies the operator of the appropriate time to replace the filter, guaranteeing a comfortable working environment.

  • Pre-filter
    When the pre-filter is 80% clogged or has been used for 200 hours, the orange indicator flashes on and off.
  • Main filter
    When the 10th pre-filter needs replacing, the orange and red lamps flash on and off.

Quiet operation and powerful suction.

Exhaust noise has been reduced without sacrificing suction performance by the addition of a silencer unit to the exhaust outlet to ensure smooth air outflow. A high-performance motor with 1,500 Pa of static pressure provides powerful suction and quiet operation.

Noise level dB (A) Air volume m3/min
HIGH 53 4.7
MEDIUM 50 3.7
LOW 44 2.8

*Values measured when the unit was used with a 60 Hz power supply.

Catch harmful smoke with freestanding ducts and adjustable air volume to suit your working environment

Is your smoke absorber affected by air conditioning? Are you fed up with having to re-adjust ducts after every line change? The HAKKO FA-430 fume extractor is the answer to your problems.

Airflow adjustment

Three airflow modes are available: High, Medium, and Low. Significantly improve your working environment by using an airflow volume that suits the worksite and the job.

  • Low mode: Not easily affected by the surrounding environment. For use in small, quiet locations. (For when low-noise operation is a priority.)
  • Medium mode: For normal use.
  • High mode: For use in locations that are significantly affected by the surrounding environment. (For when suction performance is a priority.)

What do you mean by "surrounding environment"?

Smoke flows in unexpected directions due to a variety of factors; not just because of the influence of air conditioning. High mode is recommended if your worksite is situated near a doorway, in a spot where people continuously pass by, near the exhaust outlet of a large machine, or in a similar location. It is possible to use low mode in laboratories and other places where these kinds of influences are limited.

Freestanding ducts

Ducts can be bent or lengthened as desired and maintain their shape after adjustment, letting you place them exactly where suction is needed. Say goodbye forever to ducts that are long, heavy, and hard-to-handle.

Length Weight
Duct for HAKKO FA-430 1.2m 0.6kg

Photo above:
Bends and stretches freely for perfect placement!

Photo on left:
Lightweight and compact, the HAKKO FA-430 weighs only 7.5 kg. Built-in handles allow the fume extractor to be moved easily, facilitating line changeovers.

*HAKKO FA-430 weighs 35% less than previous models

If the duct is mounted at an angle above the workpiece, it is easily affected by air conditioning

If the duct is mounted directly above, it can be difficult to see the workpiece

Duct is mounted on the worktable to provide excellent suction performance


Proper installation of the pre-filter
  • Proper installation
    Install the pre-filter inside the frame of the main filter as shown in image 1.
    Be sure to check that there are no gaps at the corners as shown in image 2.

  • Improper installation
    If the pre-filter is not installed properly as shown in images 3 and 4, the main filter will degrade its original performance quickly.
Packing List
Model No. Packing List
FA-430
Main unit, Power cord, Cap, Main filter, Pre-filters (x10), Instruction manual

Duct set (C1571/C1572) is not included in FA-430 unit. Please purchase Duct set(s) when you order FA-430 unit.

Model No. Packing List
Duct Set C1571
(With rectangular nozzle)

Duct, Adapter, Rectangular nozzle, Net, Instruction manual
Duct Set C1572
(With round nozzle)

Duct, Adapter, Round nozzle, Net, Instruction manual
Specifications
Model No. FA-430
Power consumption 110W
Noise level 50dB (MEDIUM mode)
Maximum suction capacity with single duct : MAX. 4.1m3/min. (145cfm)
with two ducts : MAX. 4.7m3/min. (167cfm)
Filtering efficiency 99.97% 0.3µm (LOW, MEDIUM mode)
99.96% 0.3µm (HIGH mode)
Static pressure 1,500Pa
Duct set (sold separately) Length of duct : Φ55mm×1.2m (ESD SAFE)
Dimensions 330(W)×366(H)×343(D)mm
Weight 7.5kg

* Filtering efficiency is an initial value of collection efficiency based on counting method for airborne dust collected by a single plate of filter (unfolded).
* Noise level is measured at a distance of 1 m from the face of unit in an anechoic room.
* Net in duct sets are not protected against electrostatic discharge.

Replacement parts
Part No. Name Specifications
A1573 Main filter
A1572 Pre-filter (qty 10)
B3619 Cap
Options
Part No. Name Specifications
C1571 Duct set with rectangular type nozzle
C1572 Duct set with round type nozzle
B3642 Duct Φ55mm×1.2m
B3620 Adapter
B3621 Adapter 3 inch
B3622 Nozzle/rectangular type
B3623 Nozzle/round type
B3625 Net (qty 5)
B2410 Duct/2m Φ75mm×2m
B2416 Duct band (qty 2)
B2418 Bench top plenum/clear
-When using an independent duct
Part No. Part Name Notes
B3642 Duct ø55 x 1.2 m
B3620 Adapter For attaching duct to main unit.

-Choose from one of 2 types of nozzles for the independent duct.
Part No. Part Name Notes
B3622 Nozzle, rectangular For absorbing smoke from the side.
B3623 Nozzle, round For absorbing smoke from above.
B3625 Net (5 per pack) For preventing contaminants from being absorbed. (Mesh dimensions: Approx. 10 mm × 10 mm)

-When using a bench top hood

The benchtop hood detailed below requires the separate purchase of a different sized duct, duct band, and 3-inch adapter.

Part No. Part Name Notes
B2418 Benchtop hood For stopping smoke from escaping upwards without being affected by air conditioning.

*Requires ø75 duct, duct band (B2416), and 3-inch adapter (B3621).
B2410 Duct Required when using benchtop hood.

*ø75 x 2 m. Not freestanding.
B2416 Duct band Required when using benchtop hood.
B3621 Adapter (for 3-inch duct) Required when using benchtop hood and ø75 duct.
Maintenance
Category Title
How to use How to mount a pre-filter
Maintenance How to extend filter life
Video
Preview Title
Free-standing Duct
Weitere Informationen
HerstellerHakko
HerstellernummerFA430-12
Lieferzeit2-3 Tage