The product may differ from the illustration
Festo pneumatic cylinder for precise linear motion and defined force in automation.

Servo Drive CMMT-AS-C4-3A-EC-S1 - Festo 5340820

FESTO Original product
Net price (excl. VAT)
€1,139.94
Item FES-5340820
Manufacturer no. CMMT-AS-C4-3A-EC-S1
Personal expert advice
Brand new Specialist dealer since 2009 Original product Worldwide shipping
Product data
Manufacturer no.CMMT-AS-C4-3A-EC-S1
EAN4052568293789
Customs tariff number85044085
ConditionNew
Article
FES-5340820

Festo pneumatic cylinder for precise linear motion and defined force in automation. The key technical data of this genuine Festo article are listed below.

Fastening typeAssembly plate, screwed
installation positionOpen convection<br>vertical
Product weight [g]1.400
DisplayLED green / yellow / red
Operating elementOptional: Control unit CDSB
Complies to standardEN 61800-3<br>EN 61800-5-1<br>EN 61800-5-2<br>EN ISO 13849-1
Based on standardEN 50581<br>EN 60204-1<br>EN 61508-1<br>EN 61508-2<br>EN 61508-3<br>EN 61508-4<br>EN 61508-5<br>EN 61508-6<br>EN 61508-7<br>EN 61800-2<br>EN 62061
PermissionRCM Mark<br>TÜV<br>c UL us - Listed (OL)
KC-markKC-EMV
CE certificate (see declaration of conformity)acc. to EU-EMV Directive<br>acc. to EU Machine Directive<br>acc. to EU Low voltage Directive<br>acc. to EU-RoHS Directive
Certified awarding pointUL E331130<br>TÜV Rheinland 01/205/5640.00/18
Bearing temperature [°C]-25 to 55
ambient temperature [°C]0 to 50
Information about ambient temperatureOberhalb der Umgebungstemperatur von 40 °C ist eine Leistungsreduktion von 3 %/°C einzuhalten.
UL - ambient temperature [°C]0 to 40
Relative humidity5 - 90 %<br>Not condensing
Max. setup height [MTR]2.000
Information about max. setup heightFrom 1000 m power reduction by 1% per 100 m
Protection categoryIP20
Protection classI
Over-voltage categoryIII
Degree of contamination2
Surge voltage strength [kV]6
Material informationLABS containing materials included<br>RoHs compliant
Phase nominal operating voltage1-phase
Nominal operating voltage AC [V]230
Permitted voltage oscillations-20 % / +15 %
Input voltage range AC [V]100 to 230
Network frequency [Hz]48 to 62
Nominal current load supply [A]5,6
Peak current load supply [A]16,8
Active PFCno
Network filterintegrated
System voltage acc. to EN 61800-5-1 [V]300
Max. short circuit resistance of the network [kA]100
Network formsTT<br>TN<br>IT
Nominal voltage load supply DC [V]320
Permitted range load supply-20 %/+15 %
Max. intermediate circuit voltage DC [V]395
Braking resistance, integrated [Ohm]100
Impulse power braking resistance [kVA]1,6
Braking resistance pulse energy [Ws]230
Braking resistance nominal performance (IEC) [W]23
Braking resistance, external [Ohm]67 bis 100
Max. continuous power of the external braking resistance (IEC) [W]350
Nominal voltage logic supply DC [V]24
Permitted range logic voltage± 20 %
Power input logic supply without parking brake [A]0,5
Power input logic supply with parking brake [A]1,5
Max. power input for logic supply, parking brake and IO [A]2,3
Output voltage range AC3x (0 - Input) V
Nominal current per phase, effective [A]4
Peak current per phase, effective [A]12
Max. peak current duration [s]2
Nominal performance controller [VA]700
Peak performance [VA]2.000
Output frequency [Hz]0 to 599
Max. length motor line without ext. network filter [MTR]25
Max. output current holding brake [A]1
Max. voltage drop from logic supply to brake output [V]0,8
Quantity of inputs for motor temperature sensor1
Operating mode controllerAutotuning<br>P position controller<br>PI-speed controller<br>Setup mode<br>Interpolated operation via fieldbus<br>Cascade control<br>PI current controller for F or M<br>Profile operation with set and direct operation<br>Reference run<br>Synchronous operating modes
Operating mode2x Input-Capture (x, v, F)<br>2x Output-Trigger (x, v, F)<br>1x SYNC-interface for encoder emulation or encoder input<br>2x position sensor input<br>Sampling rate 16 kHz<br>Real time data recording<br>Field oriented control<br>Position resolution 24 bit/rev<br>PWM with 8 or 16 KHz<br>Vector modulation with 3rd harmonic
Ethernet interface, functionParameterising and commissioning
Ethernet interface, reportTCP/IP
Fieldbus interface, reportEtherCAT
Fieldbus couplingEtherCAT
Communication profileCiA402<br>CoE (CANopen over EtherCAT)<br>EoE (Ethernet over EtherCAT)<br>FoE (File over EtherCAT)
Process couplingInterpolated Mode CSP<br>Interpolated Mode CSV<br>Interpolated Mode CST<br>E/A Mode for 256 mobile sets
Fieldbus interface, transfer rate100 Mbit/s
Fieldbus interface, connection type2x socket
Fieldbus interface, connection technologyRJ45
Encoder interface, functionENDAT 2.1 sensor<br>ENDAT 2.2 sensor<br>Hiperface sensor<br>Incremental sensor<br>Nikon<br>SIN/COS sensor
Encoder interface 2, functionIncremental sensor<br>SIN/COS sensor
Synchronous interface, functionZählsignale CW/CCW<br>Encoder-Eingang A/B/Z<br>Encoderemulation A/B/Z<br>Puls-Richtungssignale CLK/DIR
Encoder output interface, propertiesmax. 16384 ppr<br>1 MHz maximale Ausgangsfrequenz
Encoder input interface, propertiesmax. 16384 ppr<br>1 MHz maximale Ausgangsfrequenz
Quantity digital logic inputs12
Switching logic inputsPNP (Positive switching)
Properties logic inputspartially freely configurable<br>not galvanically separated<br>partially safety inputs
Logic input specificationdepending on IEC 61131-2, type 3
Work area logic input [V]-3 bis 30
Quantity of high-speed logic inputs2
Time resolution of high-speed logic inputs [µs]1
Quantity digital logic outputs 24 V DC6
Switching logic outputsPNP (Positive switching)
Properties digital logic outputspartially freely configurable<br>not galvanically separated<br>partially diagnosis outputs
Max. current digital logic outputs [mA]20
Quantity of high-speed switch outputs2
Time resolution of high-speed switch outputs [µs]1
Quantity of zero potential switch outputs1
Max. current of the zero potential switch outputs [mA]50
Quantity analogue target value inputs1
Properties target value inputsDifferential inputs<br>Configurable for rotational speed<br>Configurable for current/force
Work area target value input± 10 V
Work area analogue inputs± 10 V
Impedance target value input [kOhm]70
Safety functionSafe switched off torque (STO)<br>Safe braking controls (SBC)<br>Safe stop 1 (SS1)
Safety Integrity Level (SIL)Safe switched off torque (STO) / SIL 3 / SILCL 3<br>Safe braking controls (SBC) / SIL 3 / SILCL 3
Performance Level (PL)Safe switched off torque (STO) / Category 4, Performance Level e<br>Safe braking controls (SBC) / Category 3, Performance Level e
Diagnose degree of coverage [%]97
SFF Safe Failure Fraction [%]99
Hardware error tolerance1
Quantity of safe 2-pin inputs2
Quantity of diagnosis outputs2
More Information
Manufacturer Nr.CMMT-AS-C4-3A-EC-S1
ManufacturerFesto
EAN4052568293789
Weight1.400000
HS-Code85044085
GPSR manufacturer informationFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
Article authenticityOriginal product
Condition of articleNew
SchutzartIP20
Write Your Own Review
You're reviewing:Servo Drive CMMT-AS-C4-3A-EC-S1 - Festo 5340820
Your Rating