ESD Static Field Meter - TEC

ESD Measuring

ESD field meters measure electrostatic field strength in V/m or kV/m with typical measurement ranges from 0.1 kV/m up to 200 kV/m at distances of 25-300 mm, enabling non-contact surface voltage detection down to <1 V resolution. In EPA environments, accurate field measurement is the primary diagnostic tool for identifying charge sources exceeding the IEC 61340-5-1 threshold of 100 V on conductors and 200 V on insulators - values that cannot be detected by wrist-strap testers or surface resistance meters alone. Instruments with auto-zeroing and Faraday cup compatibility allow calibrated readings traceable to national standards.

This category covers 15 ESD field meters and electrostatic voltmeters for professional use in EPA qualification, charged-insulator audits, and ionizer performance verification per IEC 61340-5-1 / ANSI/ESD S20.20. Products are selected for industrial metrology accuracy, battery or USB operation, and compatibility with EPA documentation workflows under DIN EN 61340-5-2 site audit requirements.

Key technical advantages - ESD Field Meters at a glance
0.1 kV/m - 200 kV/m range - non-contact electrostatic field measurement per IEC 61340-5-1
25-300 mm sensing distance - configurable standoff for surface and air-gap measurements
🛠 <1 V resolution - detects charge sources below the 100 V EPA action threshold
Auto-zero + Faraday cup - traceable calibration for ionizer balance verification per ANSI/ESD SP3.3
🛡 IEC 61340-5-1 / S20.20 - instrument specs aligned with international EPA qualification norms
DIN EN 61340-5-2 audit ready - supports documented EPA site surveys and periodic re-qualification

ESD Field Meter - Product Overview

Instrument Type Measurement Range Key Application Norm Reference
Handheld field meter ca. 0.1 - 100 kV/m EPA audit, charged insulator identification IEC 61340-5-1
Rotating vane fieldmeter ca. 1 V - 200 kV/m Traceable calibration, laboratory reference ANSI/ESD S20.20
Ionizer performance tester ±1 kV, decay <2 s Ion balance & decay time verification ANSI/ESD SP3.3
Stationary field monitor ca. 0.5 - 50 kV/m Continuous EPA zone monitoring, alarm output DIN EN 61340-5-2
Combination meter (field + resistance) field + 10¹ - 10¹¹ Ω Complete EPA workstation audit in one device IEC 61340-5-1, -5-2

Typical applications: Electronics manufacturing and SMT assembly line qualification (IEC 61340-5-1, IPC-A-610), semiconductor fab EPA zoning and wafer-handling audits (SEMI E78, SEMI S1/S2), medical device production area certification (ISO 13485), automotive electronics assembly and supplier audits (IATF 16949, VDA 6.3), aerospace and defense EPA compliance verification (AS9100D), ionizer periodic performance testing and decay-time logging (ANSI/ESD SP3.3).

15 ESD Field Meters in stock Handheld, stationary and combination instruments for full EPA coverage
🛡
IEC 61340-5-1 / ANSI S20.20 compliant All instruments meet international EPA measurement and audit standards
🔍
Traceable calibration available Calibration certificates and Faraday cup accessories for audit documentation
Shop By
View as Grid List

18 Items

Set Ascending Direction
per page