€3,063.85
Excl. 19% VAT , excl. Shipping Cost
Article
FES-1622904
Manufacturer Nr.
CMMP-AS-C10-11A-P3-M0
Motor Controller
Frequently Bought Together
- This Item: €3,063.85Excl. 19% VAT , excl. Shipping Cost
- Festo CMXH-ST2-C5-7-DIOP (3605478) Controller €635.77Excl. 19% VAT , excl. Shipping Cost
- Festo CMSX-P-S-C-U-F1-D-50-A (3929313) Positioner €696.07Excl. 19% VAT , excl. Shipping Cost
Total price
Fastening type | on connection plate Permanently screwed |
Product weight [g] | 3.800 |
Display | Seven segment display |
Permission | RCM mark c UL us - Listed (OL) |
CE certificate (see declaration of conformity) | acc. to EU-EMV Directive acc. to EU Machine Directive acc. to EU Low voltage Directive acc. to EU-RoHS Directive |
Bearing temperature [°C] | -25 to 70 |
ambient temperature [°C] | 0 to 40 |
Relative humidity | 0 - 90 % |
Protection category | IP10 IP20 |
Degree of contamination | 2 |
Material information | LABS containing materials included RoHs compliant |
Phase nominal operating voltage | 3-phase |
Nominal operating voltage AC [V] | 400 |
Permitted voltage oscillations | ± 10 % |
Network frequency [Hz] | 50 to 60 |
Nominal current [A] | 11 |
Network filter | integrated |
Max. intermediate circuit voltage DC [V] | 560 |
Braking resistance [Ohm] | 68 |
Impulse power braking resistance [kVA] | 8,5 |
Nominal voltage logic supply DC [V] | 24 |
Permitted range logic voltage | ± 20 % |
Power input logic supply without parking brake [A] | 1,00 |
Output voltage range AC | 3x 0 - 360 V |
Nominal output current [A] | 10,0 |
Nominal current per phase, effective [A] | 10,0 |
Peak current per phase, effective [A] | 20 |
Max. peak current duration [s] | 5 |
Nominal performance controller [VA] | 6.000 |
Peak performance [VA] | 12.000 |
Output frequency [Hz] | 0 to 1000 |
Parameterising interface | USB Ethernet Parameterising and commissioning |
Fieldbus coupling | CANopen Modbus/TCP |
Communication profile | DS301/DSP402 |
Process coupling | I/O coupling for 256 mobile sets |
Max. fieldbus transfer rate [Mbit/s] | 1 |
Bus connector | Sub-D 9 pin Plug |
Encoder output interface, properties | Resolution 16384 ppr |
Encoder output interface, function | Actual value feedback via encoder signals for speed control mode Target value for downstream switched slave actuator |
Encoder input interface, properties | HIPERFACE RS422 SINCOS EnDat 3 phasige Encodersignale |
Encoder input interface, function | In synchronous mode as a speed preset of the slave actuator Encoder signal target speed value |
Quantity digital logic inputs | 10 |
Properties logic inputs | Freely configurable Galvanically separated |
Work area logic input [V] | 8 to 30 |
Quantity digital logic outputs 24 V DC | 5 |
Properties digital logic outputs | Galvanically separated Partially freely configurable |
Max. current digital logic outputs [mA] | 100 |
Quantity analogue target value inputs | 2 |
Properties target value inputs | Differential inputs Configurable for speed Configurable for current |
Work area target value input | ± 10 V |
Impedance target value input [kOhm] | 20 |
Quantity analogue monitor outputs | 2 |
Work area monitor outputs | ± 10 V |
Resolution monitor outputs [Bit] | 9 |
Properties monitor outputs | Short circuit proof |
Certified awarding point | 01/205/5162.02/19 TÜV Rheinland |
Safety function | Safe switched off torque (STO) Safe stop 1 (SS1) |
Safety Integrity Level (SIL) | Safe switched off torque (STO) / SIL 3 / SILCL 3 |
Performance Level (PL) | Safe switched off torque (STO) / category 4 performance level e |
Diagnose degree of coverage [%] | 97 |
SFF Safe Failure Fraction [%] | 99,17 |
Hardware error tolerance | 1 |
Proof test interval [A] | 20 |
Manufacturer Nr. | CMMP-AS-C10-11A-P3-M0 |
---|---|
Manufacturer | Festo |
EAN | 4052568243272 |
Weight | 4.200000 |
HS-Code | 85044085 |
Customers Who Bought This Item Also Bought