Fume Extractions

Reeco Solder Fume Extraction

Solder fume forms right in the operator breathing zone and carries flux residue and fine dust. Extraction at the bench captures it where it appears instead of spreading it through the room ventilation. The RE-FCE-001 has two extraction arms, each 1400 mm long and 60 mm in diameter, and serves two workstations which may sit up to two and a half metres apart.

Filtration runs in three stages: a pre-filter for coarse particles, a class F8 medium filter for fine pre-filtration and a class H11 carbon main filter for microparticles around 0.3 µm and vapours. A filter monitor reports falling performance. The unit is mobile, ESD safe and set in ten power levels from the control panel or the supplied wireless remote.

  • 4 items
  • 1 manufacturer
  • Net prices plus VAT
View as Grid view List view

4 Items

Set Descending Direction
per page
  1. ESD solder fume extractor for 2 benches, HEPA, 210 W - Reeco RE-FCE-001
    €793.80

Buying guide

How to choose Reeco Solder Fume Extraction

What matters when choosing: properties, comparison and typical applications.

Features and equipment

⚡ Two 1400 mm extraction arms - one unit for two workstations
⚙ Three-stage filtration - pre-filter, F8 medium filter, H11 carbon main filter
↔ Ten power levels - control panel or wireless remote
✓ Filter monitoring with alarm - reports a due change before performance drops
🛡 ESD safe build - use inside the EPA, steel housing, mobile

Unit and consumables

ArticleFunctionKey figureService life
RE-FCE-001Extractor with two arms210 W, 20.5 kg, ten levelsmain unit
RE-FCE-002Pre-filter365 x 180 x 5 mmfirst stage, changed most often
RE-FCE-003Medium filterclass F8, 365 x 175 x 55 mmabout 2 to 3 months
RE-FCE-004Carbon main filterclass H11, particles around 0.3 µmfinal stage, changed on alarm

Typical applications

Typical applications: Hand soldering and rework benches, rework and repair, bonding and potting, laboratory and small series production, training and test benches where fume and vapour have to be caught at source.

✓ HEPA main filtermicroparticles around 0.3 µm and vapours
⚡ 2 workstationsarms reach up to two and a half metres apart