Charge plate set CPS for ionizer monitoring to EN 61340-5-1
The CPS upgrade set turns a electric field meter into a charge plate monitor for testing air ionizers. It measures the decay time from ±1,000 V to ±100 V reproducibly with an integrated start-stop timer. Electric field meter not included.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The charge plate set CPS upgrades a Safeguard electric field meter into a charge plate monitor, letting you verify the performance of air ionizers directly at the workstation. The charge electrode is charged via an external HV converter, and the integrated start-stop timer records the decay time reproducibly.
Your benefits
- Turns the field meter into a measuring system for ionizer monitoring to DIN EN 61340-5-1 and EOS/ESD S3.1.
- Plate capacitor with a standard-compliant capacitance of 20 pF for decay time measurement.
- Reproducible decay time measurements from +1,000 V to +100 V and from -1,000 V to -100 V.
- Supplied complete in a carry case with battery, charger and grounding accessories.
Application
Suitable for periodic verification and monitoring of ionizing equipment in EPA areas of electronics manufacturing, repair and quality assurance.
Standards and compliance
Supports the testing of ionizers in accordance with DIN EN 61340-5-1 and EOS/ESD S3.1.
Technical data
| Measuring principle | plate capacitor with start-stop timer, decay time measurement ±1,000 V to ±100 V |
|---|---|
| Plate capacitor capacitance | 20 pF ±2 pF, plate gap approx. 10 mm |
| Plate dimensions | approx. 75 mm x 150 mm (L x W), capacitance standard-compliant, size differs from the 150 mm x 150 mm standard |
| HV converter | charge voltage approx. > 1,100 V, size approx. 86 mm x 64 mm x 26 mm (L x W x H) |
| CPS base | conductive foam / aluminium, grounding via 2x banana plugs, approx. 75 mm x 150 mm x 35 mm |
| Overall dimensions | approx. 150 mm x 125 mm x 75 mm (L x W x H) |
| Note | in CPS mode only voltages up to max. 2 kV are displayed |
| Weight | 0.1 kg |
| Manufacturer | Safeguard |
| Manufacturer Nr. | CPS PRO |
| GPSR manufacturer information | KW-SG Elektrotechnik GmbH Industriestraße 11 AT-9601 Arnoldstein www.kwsg.at |
| Condition of article | New |
| Article authenticity | Original product |
| Sales unit | 1 Stück |
| Height | 75 |
| Width | 125 |
| Depth | 150 |
| ESD version | ESD (antistatic) |
| Norm | ESD S3.1, DIN EN 61340-5-1 |
| Certification | IEC 61340-5-1 |
Scope of delivery
- HV converter with charge voltage approx. > 1,100 V
- 9 V NiMH battery and plug-in charger EC109
- CPS base (conductive foam / aluminium) with plate capacitor
- Grounding cables 1 m and 1.5 m plus crocodile clip
- Carry case and operating instructions
Important: The Safeguard electric field meter is not included and is required for operation.