Images are for illustration purposes only and may differ from the actual product. Some images have been generated or edited, in whole or in part, using artificial intelligence systems. The technical specifications in the product description are authoritative.
The plug is the insert half of the connection and enters the socket of the same size. It is normally fitted to the side that moves, gets swapped or travels with the job, such as a hose, a tool or a test piece. Plugs in this series are available in brass, steel and stainless steel with NBR or FKM seals. Model MALC-01TP-FL, BRASS, Seal material NBR.

Quick connect coupling Multi Cupla MALC-01TP-FL, BRASS - Nitto Kohki 369862380

NITTO KOHKI Original product
Net price (excl. VAT)
€43.84
Item NKH-369862380
Manufacturer no. 369862380
Personal expert advice
Brand new Specialist dealer since 2009 Original product Worldwide shipping
Product data
Manufacturer no.369862380
ConditionNew
Article
NKH-369862380

On machines and test rigs, lines are disconnected and reconnected several times a day. The Multi Cupla series from Nitto Kohki covers that job with 120 versions in brass, steel or stainless steel, each available as a socket and as the matching plug.

  • Bodies in brass, steel or stainless steel (SUS), so the coupling suits the environment at the installation point.
  • Seals in NBR or FKM, which lets the material pairing be matched to the medium being carried.
  • Every socket has a plug of the same size, for example MALC-4S and MALC-4P, which keeps spare part stocking simple.
  • Sizes 01, 1, 2, 3, 4, 6 and 8 within the same model line, so different port sizes stay inside one coupling system.
  • 120 articles in a single series, from the individual coupling to the MAM, MALC, MALS, MALT, MAS and MAT versions.

Technical data from the manufacturer catalogue

SeriesMULTI CUPLA MALC Type
ModelMALC-01TP-FL
Coupling partPlug
End connectionWith flange
Port sizeSee drawings below.
Body materialMALC-01 Type: Socket Brass (Nickel plated), Plug Brass (Nickel plated), MALC-SP Type: Stainless steel (Socket body: Nickel plated), MALC-HSP Type: Special steel (Nickel plated)
Seal materialNBR (Nitrile rubber), FKM (Fluoro rubber)
Max working pressureMALC-01 Type: 1.0 MPa {10 kgf/cm2}; MALC-SP Type: 1.5 to 7.0 MPa {15 to 71 kgf/cm2}; MALC-HSP Type: 21.0 to 25.0 MPa {214 to 255 kgf/cm2}
Working temperatureNBR (Nitrile rubber), MALC-01 Type: -20 to +80 deg C | FKM (Fluoro rubber), MALC-SP Type: -20 to +180 deg C | FKM (Fluoro rubber), MALC-HSP Type: -20 to +180 deg C
Valve structureMALC-01 Type: One-way shut-off; MALC-SP Type: Two-way shut-off (Spill Reduction); MALC-HSP Type: Two-way shut-off (Spill Reduction)
Applicable fluidsAir, Water, Hydraulic oil
Vacuum serviceNot suitable for vacuum application in either connected or disconnected condition.
Size rangeMALC-01 Type: one size; MALC-SP Type: sizes 1, 2, 3, 4, 6, 8 and 12; MALC-HSP Type: sizes 1, 2, 3, 4, 6 and 8
MALC-01 working pressure1.0 MPa, 10 kgf/cm2, 10 bar, 145 PSI
MALC-01 maximum tightening torque thread screw mount15 Nm {153 kgf cm}
MALC-01 maximum tightening torque flange1.5 Nm {15 kgf cm}
MALC-01 acceptable distance between CUPLA0 to 0.5 mm. Socket and plug or plate must be used in contact with each other. Maximum 0.5 mm distance between socket and plug or plate is acceptable.
MALC-SP model / end configuration overviewThread screw mount: MALC-1SP, MALC-2 to 8SP, MALC-12SP. Flange: MALC-2 to 8SP-FL. Snap ring: MALC-8SP-10F, MALC-12SP(-F/-16F).
MALC-SP working pressure MALC-1SP (individual unit)7.0 (2.0) MPa, 71 (20) kgf/cm2, 70 (20) bar, 1020 (290) PSI
Mass0.050 kg
Part number369862380
Catalogue pageC01en-b, 133

Dimensions

Plug dimension sketchPlug dimension sketchLHASchematic view of the dimension letters, not to scale.
How the dimension letters in the table map onto the part.
ModelHAøL1øL2øL3øL4øoBøoD
MALC-01TP-FL36120 deg28(14)143.26(22)

Dimensions in millimetres. Values in brackets apply in the connected condition.

Legend: H = width across flats or outside dimension; A = hose barb length

Models in this series MULTI CUPLA MALC Type

ModelApplicationBrass (g)Stainless steel (g)Steel (g)HATøH(WAF)øL1øL2øL3øL4øSøoBøoD
MALC-01TPSee drawings below.40----M14x1Hex.1728(14)14--618.5
MALC-01SSee drawings below.39----M14x1Hex.17(41)(20.5)16---18.5
MALC-01TP-FLSee drawings below.52--36120 deg--28(14)143.2-6(22)
MALC-01S-FLSee drawings below.51--36120 deg--(41)(20.5)163.2--(22)
MALC-1PSee page 137-40---M16x1Hex.1932(18)14---21
MALC-2PSee page 137-75---M20x1.5Hex.2633(20)13---28
MALC-3PSee page 137-95---M24x1.5Hex.2933(20)13---32
MALC-4PSee page 137-248---M35x1.5Hex.4141(28)13---45
MALC-6PSee page 137-369---M40x2Hex.4650.5(37.5)13---50
MALC-8PSee page 137-399---M45x2Hex.5053(41)12---54
MALC-12PSee page 137-724---M62x2Hex.6757(45)12---74
MALC-1SSee page 137-53---M16x1Hex.19(45)(23)16---21
MALC-2SSee page 137-95---M20x1.5Hex.26(49)(26)17---28
MALC-3SSee page 137-120---M24x1.5Hex.29(51)(26)17---32
MALC-4SSee page 137-306---M35x1.5Hex.41(64)(36.5)17---45
MALC-6SSee page 137-471---M40x2Hex.46(78.5)(47.5)17---50
MALC-8SSee page 137-590---M45x2Hex.50(86)(53)18---54
MALC-12SSee page 137-1176---M62x2Hex.67(98)(60)18---74
MALC-2P-FLSee page 137-146-----30(17)6-40--
MALC-3P-FLSee page 137-180-----33(20)6-45--
MALC-4P-FLSee page 137-390-----41(28)6.5-58--
MALC-6P-FLSee page 137-553-----50.5(37.5)6.5-64--
MALC-8P-FLSee page 137-796-----53(41)12-79--
MALC-2S-FLSee page 137-173-----(49)(26)6-40--
MALC-3S-FLSee page 137-208-----(51)(26)6-45--
MALC-4S-FLSee page 137-449-----(64)(36.5)6.5-58--
MALC-6S-FLSee page 137-663-----(78.5)(47.5)6.5-64--
MALC-8S-FLSee page 137-978-----(86)(53)181279--
MALC-8P-10FSee drawings below.-1182---Rc 1 1/454(87)75(12)---64
MALC-12P-FSee drawings below.-2054---Rc 1 1/258(97)85(12)---84
MALC-12P-16FSee drawings below.-2128---Rc 271(97)85(12)---84
MALC-8S-10FSee drawings below.-1373---Rc 1 1/454(108)75(18)---64
MALC-12S-FSee drawings below.-2505---Rc 1 1/258(123)85(18)---84
MALC-12S-16FSee drawings below.-2579---Rc 271(123)85(18)---84
MALC-1HPSee page 141--39--M16x1Hex.1932(18)14---21
MALC-2HPSee page 141--73--M20x1.5Hex.2633(20)13---28
MALC-3HPSee page 141--96--M24x1.5Hex.2933(20)13---32
MALC-4HPSee page 141--250--M35x1.5Hex.4141(28)13---45
MALC-6HPSee page 141--357--M40x2Hex.4650.5(37.5)13---50
MALC-8HPSee page 141--391--M45x2Hex.5053(41)12---54

Every model of the series as printed in the manufacturer catalogue. The row of the article offered here is highlighted.

Operating principle

Two-way shut-offTwo-way shut-offshut-off valve in socketshut-off valve in plugSocketPlugFlow direction: socket to plug
Both halves close on disconnection, so the line contents are retained on both sides.
  • MALC-01 Type: Solo use of socket is possible.
  • MALC-01 Type: As in the case of MULTI CUPLA MALC-SP type and MALC-HSP type, the distance between the socket plate and the plug plate is designed to be 30 mm when connected. This means MULTI CUPLA MALC-01 type can also be installed mixed with any size of MALC-SP type and MALC-HSP type on the same plate.
  • MALC-01 Type: An axial eccentricity allowance of 2 mm eliminates precise centering at installation.
  • MALC-01 Type: Compact size with thread screw mount and with flange types available.
  • MALC-01 Type: Suitable for operation of ejector pins to open/close valve gates in molding.
  • MALC-SP Type: Compared with conventional MULTI CUPLA, approximately double flow rates are realized. This could reduce the size of required plates. (Rate of flow increase depends on CUPLA sizes.)
  • MALC-SP Type: The MALC type realizes a 2 mm axial eccentricity allowance, while conventional MULTI CUPLA is only 0.6 mm.
  • MALC-SP Type: Special valve design enables connection of socket and plug under pressure of up to 2 MPa. (up to 1.5 MPa for MALC-12SP.)

Series comparison

SeriesMax working pressureSize rangeValve structureApplicable fluids
MULTI CUPLA MALC TypeMALC-01 Type: 1.0 MPa {10 kgf/cm2}; MALC-SP Type: 1.5 to 7.0MALC-01 Type: one size; MALC-SP Type: sizes 1, 2, 3, 4, 6, 8 and 12; MALC-HSP Type: sizes 1, 2, 3, 4, 6 and 8MALC-01 Type: One-way shut-off; MALC-SP Type: Two-way shut-off (Spill Reduction); MALC-HSP Type: Two-way shut-off (Spill Reduction)Air, Water, Hydraulic oil
MULTI CUPLA MAM Type7 barRc 1/8One-way shut-off (valve on socket side only)Air
MULTI CUPLA MAM-B Type10 bar1/8 inch (8 and 12 port plates), 1/4 inch (6 and 8 port plates)Two-way shut-offAir, Water
MULTI CUPLA MAM-A Type10 bar1/4 inch to 1/2 inch for MAM-A Type plates with CUPLA; 1/8 inch to 1/2 inch for individual CUPLA of MAM-A-SP Type; 1/4 inch to 1/2 inch for individual CUPLA of MAM-A-ZEL TypeTwo-way shut-offAir, Water
MULTI CUPLA MAS Type / MAT Type70 bar1/4 inch, 3/8 inch, 1/2 inch, 3/4 inch, 1 inch (MAS type thread); M20, M24, M30, M39, M45 (MAT type thread)Two-way shut-offAir, Water, Hydraulic oil
MULTI CUPLA MAS Type / MAT Type and MALC-01 Type70 barMAS type 1/4 inch, 3/8 inch, 1/2 inch, 3/4 inch, 1 inch (R and Rc threads); MAT type M20, M24, M30, M39, M45 thread screw mount; MALC-01 type M14x1 thread screw mount or flangeTwo-way shut-off for MAS type and MAT type; One-way shut-off for MALC-01 typeAir, Water, Hydraulic oil

MULTI CUPLA MALC is the choice as soon as the pressure class exceeds what the other MULTI CUPLA plates cover: MAM Type ends at 0.7 MPa {7 kgf/cm2}, MAM-A Type and MAM-B Type at 1.0 MPa {10 kgf/cm2} and MAS Type / MAT Type at 7.0 MPa {71 kgf/cm2}, while MALC-SP Type covers 1.5 to 7.0 MPa {15 to 71 kgf/cm2} and MALC-HSP Type 21.0 to 25.0 MPa {214 to 255 kgf/cm2}. Within the range MALC-SP Type and MALC-HSP Type shut off on both sides with spill reduction, so they fit lines where outflow of fluid and air admixture matter, whereas MALC-01 Type at 1.0 MPa {10 kgf/cm2} is one-way shut-off like MAM Type. A further reason for MALC is mixed assembly: the 30 mm plate distance is the same for all three sub-types and all sizes, so one plate can carry different sizes and pressure classes.

Body and seal materials

Body material
MALC-01 Type: Socket Brass (Nickel plated), Plug Brass (Nickel plated)
MALC-SP Type: Stainless steel (Socket body: Nickel plated)
MALC-HSP Type: Special steel (Nickel plated)
Seal materialMarkWorking temperatureRemarks
NBR (Nitrile rubber), MALC-01 Type--20 to +80 deg C-
FKM (Fluoro rubber), MALC-SP Type--20 to +180 deg C-
FKM (Fluoro rubber), MALC-HSP Type--20 to +180 deg C-

Applications

  • Tool and fixture changes where lines are disconnected on a regular basis
  • Test and measuring benches with changing setups
  • Plant modules that are uncoupled quickly for service and rebuilds
  • Installation points in corrosive surroundings, which is what the stainless steel (SUS) versions are intended for

Safety and application notes

  • MALC-01 Type: socket and plug or plate must be used in contact with each other. Maximum 0.5 mm distance between socket and plug or plate is acceptable.
  • MALC-SP Type and MALC-HSP Type: plug and socket must be used in contact with each other. Maximum 0.5 mm distance between socket and plug is acceptable.
  • For solo use of the MALC-01 socket, the angle of inclination between the socket and the counterpart must be within 0.5 degrees.
  • Maintain the connection with the minimum load or more, but not more than the maximum acceptable load. For MALC-01 Type the maximum acceptable load is 500 N {51 kgf}.
  • Before use, please be sure to read the Safety Guide described at the end of this book and the Instruction Sheet that comes with the products.

All technical data on this page is taken from the Nitto Kohki general catalogue Quick Connect Couplings C01en-b, page 133. The complete catalogue is available for download on this page.

More Information
Weight 0.050000
Manufacturer Nitto Kohki
Manufacturer Nr. 369862380
GPSR manufacturer information Nitto Kohki Europe GmbH, Gottlieb-Daimler-Str. 10, DE-71144 Steinenbronn, www.nitto-kohki.eu
Condition of article New
Article authenticity Original product
Material Brass