Images are for illustration purposes only and may differ from the actual product. Some images have been generated or edited, in whole or in part, using artificial intelligence systems. The technical specifications in the product description are authoritative.
The plug is the insert half of the connection and enters the socket of the same size. It is normally fitted to the side that moves, gets swapped or travels with the job, such as a hose, a tool or a test piece. Plugs in this series are available in brass, steel and stainless steel with NBR or FKM seals. Model MALC-01TP-FL, BRASS, Seal material NBR.
On machines and test rigs, lines are disconnected and reconnected several times a day. The Multi Cupla series from Nitto Kohki covers that job with 120 versions in brass, steel or stainless steel, each available as a socket and as the matching plug.
Bodies in brass, steel or stainless steel (SUS), so the coupling suits the environment at the installation point.
Seals in NBR or FKM, which lets the material pairing be matched to the medium being carried.
Every socket has a plug of the same size, for example MALC-4S and MALC-4P, which keeps spare part stocking simple.
Sizes 01, 1, 2, 3, 4, 6 and 8 within the same model line, so different port sizes stay inside one coupling system.
120 articles in a single series, from the individual coupling to the MAM, MALC, MALS, MALT, MAS and MAT versions.
How the dimension letters in the table map onto the part.
Model
H
A
øL1
øL2
øL3
øL4
øoB
øoD
MALC-01TP-FL
36
120 deg
28
(14)
14
3.2
6
(22)
Dimensions in millimetres. Values in brackets apply in the connected condition.
Legend: H = width across flats or outside dimension; A = hose barb length
Models in this series MULTI CUPLA MALC Type
Model
Application
Brass (g)
Stainless steel (g)
Steel (g)
H
A
T
øH(WAF)
øL1
øL2
øL3
øL4
øS
øoB
øoD
MALC-01TP
See drawings below.
40
-
-
-
-
M14x1
Hex.17
28
(14)
14
-
-
6
18.5
MALC-01S
See drawings below.
39
-
-
-
-
M14x1
Hex.17
(41)
(20.5)
16
-
-
-
18.5
MALC-01TP-FL
See drawings below.
52
-
-
36
120 deg
-
-
28
(14)
14
3.2
-
6
(22)
MALC-01S-FL
See drawings below.
51
-
-
36
120 deg
-
-
(41)
(20.5)
16
3.2
-
-
(22)
MALC-1P
See page 137
-
40
-
-
-
M16x1
Hex.19
32
(18)
14
-
-
-
21
MALC-2P
See page 137
-
75
-
-
-
M20x1.5
Hex.26
33
(20)
13
-
-
-
28
MALC-3P
See page 137
-
95
-
-
-
M24x1.5
Hex.29
33
(20)
13
-
-
-
32
MALC-4P
See page 137
-
248
-
-
-
M35x1.5
Hex.41
41
(28)
13
-
-
-
45
MALC-6P
See page 137
-
369
-
-
-
M40x2
Hex.46
50.5
(37.5)
13
-
-
-
50
MALC-8P
See page 137
-
399
-
-
-
M45x2
Hex.50
53
(41)
12
-
-
-
54
MALC-12P
See page 137
-
724
-
-
-
M62x2
Hex.67
57
(45)
12
-
-
-
74
MALC-1S
See page 137
-
53
-
-
-
M16x1
Hex.19
(45)
(23)
16
-
-
-
21
MALC-2S
See page 137
-
95
-
-
-
M20x1.5
Hex.26
(49)
(26)
17
-
-
-
28
MALC-3S
See page 137
-
120
-
-
-
M24x1.5
Hex.29
(51)
(26)
17
-
-
-
32
MALC-4S
See page 137
-
306
-
-
-
M35x1.5
Hex.41
(64)
(36.5)
17
-
-
-
45
MALC-6S
See page 137
-
471
-
-
-
M40x2
Hex.46
(78.5)
(47.5)
17
-
-
-
50
MALC-8S
See page 137
-
590
-
-
-
M45x2
Hex.50
(86)
(53)
18
-
-
-
54
MALC-12S
See page 137
-
1176
-
-
-
M62x2
Hex.67
(98)
(60)
18
-
-
-
74
MALC-2P-FL
See page 137
-
146
-
-
-
-
-
30
(17)
6
-
40
-
-
MALC-3P-FL
See page 137
-
180
-
-
-
-
-
33
(20)
6
-
45
-
-
MALC-4P-FL
See page 137
-
390
-
-
-
-
-
41
(28)
6.5
-
58
-
-
MALC-6P-FL
See page 137
-
553
-
-
-
-
-
50.5
(37.5)
6.5
-
64
-
-
MALC-8P-FL
See page 137
-
796
-
-
-
-
-
53
(41)
12
-
79
-
-
MALC-2S-FL
See page 137
-
173
-
-
-
-
-
(49)
(26)
6
-
40
-
-
MALC-3S-FL
See page 137
-
208
-
-
-
-
-
(51)
(26)
6
-
45
-
-
MALC-4S-FL
See page 137
-
449
-
-
-
-
-
(64)
(36.5)
6.5
-
58
-
-
MALC-6S-FL
See page 137
-
663
-
-
-
-
-
(78.5)
(47.5)
6.5
-
64
-
-
MALC-8S-FL
See page 137
-
978
-
-
-
-
-
(86)
(53)
18
12
79
-
-
MALC-8P-10F
See drawings below.
-
1182
-
-
-
Rc 1 1/4
54
(87)
75
(12)
-
-
-
64
MALC-12P-F
See drawings below.
-
2054
-
-
-
Rc 1 1/2
58
(97)
85
(12)
-
-
-
84
MALC-12P-16F
See drawings below.
-
2128
-
-
-
Rc 2
71
(97)
85
(12)
-
-
-
84
MALC-8S-10F
See drawings below.
-
1373
-
-
-
Rc 1 1/4
54
(108)
75
(18)
-
-
-
64
MALC-12S-F
See drawings below.
-
2505
-
-
-
Rc 1 1/2
58
(123)
85
(18)
-
-
-
84
MALC-12S-16F
See drawings below.
-
2579
-
-
-
Rc 2
71
(123)
85
(18)
-
-
-
84
MALC-1HP
See page 141
-
-
39
-
-
M16x1
Hex.19
32
(18)
14
-
-
-
21
MALC-2HP
See page 141
-
-
73
-
-
M20x1.5
Hex.26
33
(20)
13
-
-
-
28
MALC-3HP
See page 141
-
-
96
-
-
M24x1.5
Hex.29
33
(20)
13
-
-
-
32
MALC-4HP
See page 141
-
-
250
-
-
M35x1.5
Hex.41
41
(28)
13
-
-
-
45
MALC-6HP
See page 141
-
-
357
-
-
M40x2
Hex.46
50.5
(37.5)
13
-
-
-
50
MALC-8HP
See page 141
-
-
391
-
-
M45x2
Hex.50
53
(41)
12
-
-
-
54
Every model of the series as printed in the manufacturer catalogue. The row of the article offered here is highlighted.
Operating principle
Both halves close on disconnection, so the line contents are retained on both sides.
MALC-01 Type: Solo use of socket is possible.
MALC-01 Type: As in the case of MULTI CUPLA MALC-SP type and MALC-HSP type, the distance between the socket plate and the plug plate is designed to be 30 mm when connected. This means MULTI CUPLA MALC-01 type can also be installed mixed with any size of MALC-SP type and MALC-HSP type on the same plate.
MALC-01 Type: An axial eccentricity allowance of 2 mm eliminates precise centering at installation.
MALC-01 Type: Compact size with thread screw mount and with flange types available.
MALC-01 Type: Suitable for operation of ejector pins to open/close valve gates in molding.
MALC-SP Type: Compared with conventional MULTI CUPLA, approximately double flow rates are realized. This could reduce the size of required plates. (Rate of flow increase depends on CUPLA sizes.)
MALC-SP Type: The MALC type realizes a 2 mm axial eccentricity allowance, while conventional MULTI CUPLA is only 0.6 mm.
MALC-SP Type: Special valve design enables connection of socket and plug under pressure of up to 2 MPa. (up to 1.5 MPa for MALC-12SP.)
1/8 inch (8 and 12 port plates), 1/4 inch (6 and 8 port plates)
Two-way shut-off
Air, Water
MULTI CUPLA MAM-A Type
10 bar
1/4 inch to 1/2 inch for MAM-A Type plates with CUPLA; 1/8 inch to 1/2 inch for individual CUPLA of MAM-A-SP Type; 1/4 inch to 1/2 inch for individual CUPLA of MAM-A-ZEL Type
Two-way shut-off
Air, Water
MULTI CUPLA MAS Type / MAT Type
70 bar
1/4 inch, 3/8 inch, 1/2 inch, 3/4 inch, 1 inch (MAS type thread); M20, M24, M30, M39, M45 (MAT type thread)
Two-way shut-off
Air, Water, Hydraulic oil
MULTI CUPLA MAS Type / MAT Type and MALC-01 Type
70 bar
MAS type 1/4 inch, 3/8 inch, 1/2 inch, 3/4 inch, 1 inch (R and Rc threads); MAT type M20, M24, M30, M39, M45 thread screw mount; MALC-01 type M14x1 thread screw mount or flange
Two-way shut-off for MAS type and MAT type; One-way shut-off for MALC-01 type
Air, Water, Hydraulic oil
MULTI CUPLA MALC is the choice as soon as the pressure class exceeds what the other MULTI CUPLA plates cover: MAM Type ends at 0.7 MPa {7 kgf/cm2}, MAM-A Type and MAM-B Type at 1.0 MPa {10 kgf/cm2} and MAS Type / MAT Type at 7.0 MPa {71 kgf/cm2}, while MALC-SP Type covers 1.5 to 7.0 MPa {15 to 71 kgf/cm2} and MALC-HSP Type 21.0 to 25.0 MPa {214 to 255 kgf/cm2}. Within the range MALC-SP Type and MALC-HSP Type shut off on both sides with spill reduction, so they fit lines where outflow of fluid and air admixture matter, whereas MALC-01 Type at 1.0 MPa {10 kgf/cm2} is one-way shut-off like MAM Type. A further reason for MALC is mixed assembly: the 30 mm plate distance is the same for all three sub-types and all sizes, so one plate can carry different sizes and pressure classes.
Tool and fixture changes where lines are disconnected on a regular basis
Test and measuring benches with changing setups
Plant modules that are uncoupled quickly for service and rebuilds
Installation points in corrosive surroundings, which is what the stainless steel (SUS) versions are intended for
Safety and application notes
MALC-01 Type: socket and plug or plate must be used in contact with each other. Maximum 0.5 mm distance between socket and plug or plate is acceptable.
MALC-SP Type and MALC-HSP Type: plug and socket must be used in contact with each other. Maximum 0.5 mm distance between socket and plug is acceptable.
For solo use of the MALC-01 socket, the angle of inclination between the socket and the counterpart must be within 0.5 degrees.
Maintain the connection with the minimum load or more, but not more than the maximum acceptable load. For MALC-01 Type the maximum acceptable load is 500 N {51 kgf}.
Before use, please be sure to read the Safety Guide described at the end of this book and the Instruction Sheet that comes with the products.
All technical data on this page is taken from the Nitto Kohki general catalogue Quick Connect Couplings C01en-b, page 133. The complete catalogue is available for download on this page.