Images are examples, some edited with AI. The technical data are authoritative. AI notice
ESD grounding connection set for floor coverings up to 10 x 20 m
Complete grounding connection set for ESD floor coverings up to 10 m x 20 m. With a 4 mm test point for resistance measurement, copper grounding tape, cable and mounting hardware.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The grounding connection set links an ESD floor covering of up to 10 m x 20 m to ground in a controlled way. The wall-mounted connection box offers a 4 mm connection point for measuring the floor resistance with a high-resistance meter.
Benefits
- Grounds an area of up to 10 m x 20 m
- 4 mm test point for floor resistance measurement
- Complete kit with tape, cable and fixings
Application
Grounding of ESD floor coverings in EPA areas of electronics manufacturing.
Standards
Suitable for building EPA areas to IEC 61340-5-1.
Technical data
| Connection box dimensions | 45 mm x 55 mm x 10 mm |
|---|---|
| Mounting | wall mount |
| Test point | 4 mm for high-resistance meter |
| Weight | 0.1 kg |
| Manufacturer | A1-ESD |
| Manufacturer Nr. | EP0102007 |
| GPSR manufacturer information | A1-ESD equipment GmbH. Keldersstr. 15, DE-42697 Solingen, www.esd.equipment |
| Condition of article | New |
| Article authenticity | Original product |
| Sales unit | 1 Set |
| Height | 55 |
| Width | 45 |
| Depth | 10 |
| ESD version | ESD (antistatic) |
| Certification | IEC 61340-5-1 |
Scope of delivery
- 2 m of self-adhesive copper grounding tape
- 3 m green-yellow cable with M5 ring terminal
- 2 screws
- 6 cable clips
- 1 spare M5 ring terminal
Downloads
Accessories
Questions about this item
Bei dem Artikel EP0102007 habe ich folgende Frage:
Mit welchem flexiblen Leiterquerschnitt bzw. muss der Artikel angeschlossen werden?
Answered
Der Leiterquerschnitt ist für die ESD-Funktion nicht kritisch: IEC 61340-5-1 legt nur Widerstandswerte fest (Erdableitwiderstand Rg < 1 × 10⁹ Ω), keinen Querschnitt. Da das Set an den Schutzleiter bzw. die Potentialausgleichsschiene des Gebäudes angeschlossen wird, empfehlen wir, die Vorgaben für Schutz- und Potentialausgleichsleiter nach DIN VDE 0100-540 einzuhalten: flexible Leitung H07V-K grün-gelb, mindestens 2,5 mm² bei geschützter Verlegung (Kabelkanal, Rohr) bzw. 4 mm² bei ungeschützter Verlegung. Der Anschluss erfolgt über einen M5-Ringkabelschuh passend zum Querschnitt und sollte von einer Elektrofachkraft ausgeführt werden.
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.