Mipolam Biocontrol ESD+

Floor coverings

Mipolam Biocontrol ESD+ is the covering for cases where the usual 100 V body voltage limit is not enough. To IEC 61340-4-5 and ANSI/ESD STM 97.2 the charge stays below 35 V. The homogeneous vinyl is 2 mm thick, supplied as a 200 cm x 20 m roll, and is suitable for cleanrooms. Measured in the laboratory, resistance to ground is below 106 Ω; the normative figure to IEC 61340-5-1 and ANSI/ESD S20.20 is below 109 Ω.

Body voltage below 35 V - to IEC 61340-4-5 and ANSI/ESD STM 97.2, measured with ESD footwear to S20.20 and IEC 61340-5-1
Conductive, Rg ≤ 106 Ω to EN 1081 and EN 14041 - laboratory measurements to IEC 61340-4-1 and ANSI/ESD STM 7.1 put Rgp and Rpp below 106 Ω
Suitable for cleanrooms - same product family as Biocontrol EL5, Evercare™ surface treatment, antibacterial and antiviral tested
Roll 200 cm x 20 m, 2.0 mm, 2980 g/m² - homogeneous type I build, impact sound reduction 5 dB
📦 Colour 1000 Graphite - NCS 4005-R80B, LRV 29.7, the dark shade keeps marks discreet in high security areas
Use class 34 - 43, Bfl-s1, R9 - highest commercial and industrial class to EN ISO 10874

PropertyStandardValue
Overall thicknessEN ISO 243462,0 mm
Weight per areaEN ISO 239972980 g/m²
Roll widthEN ISO 24341200 cm
Roll lengthEN ISO 2434120 m
Installation method-fully bonded
Binder contentEN ISO 10581Typ I
Product standard-EN ISO 10581
European classificationEN ISO 1087434 - 43
Reaction to fireEN 13501-1Bfl-s1
Electrical resistanceEN 1081 / EN 14041Rg ≤ 106
Electrical resistanceIEC 61340-4-1 / IEC 61340-5-1Rgp < 109 (normativ), Rgp < 106 (Labor)
Electrical resistanceANSI/ESD STM 7.1 / S20.20Rgp und Rpp < 109 (normativ), < 106 (Labor)
Body voltage generationEN 1815< 2 kV
Body voltage generationIEC 61340-4-5 / ANSI/ESD STM 97.2< 35 V
ESD protectionIEC 61340-5-1 / ANSI/ESD S20.20compliant
Slip resistanceDIN 51130R9
Impact sound reductionEN ISO 717-25 dB
Dimensional stabilityEN ISO 23999≤ 0,4 %
Residual indentationEN ISO 24343-1≤ 0,1 mm
Castor chair suitabilityISO 4918yes, type W
Thermal conductivityEN ISO 104560,25 W/(m·K)
Colour fastness to lightEN ISO 105-B02≥ 6
Surface treatment-Evercare™
Antibacterial activityISO 22196> 99 % growth inhibition
Antiviral activityISO 2170299.7 % after 2 h, 99.9 % after 5 h
Chemical resistanceEN ISO 26987very good resistance
TVOC after 28 daysISO 16000-6< 10 µg/m³
Certificate-FloorScore™
CE markingEN 14041compliant

Complete values including test conditions are given in the Mipolam Biocontrol ESD+ data sheet available for download in this category. Resistance values are measured before installation.

ColourArticle numberNCSLRV
1000 Graphite8667-10004005-R80B29,7

The LRV values (light reflectance value) support lighting and contrast planning, the NCS notation helps to match wall and furniture colours.

Typical applications: manufacturing and testing of highly sensitive class 0 devices to ANSI/ESD S20.20, semiconductor back end and wafer handling, cleanrooms with combined ESD and particle requirements, aerospace and medical device production, and test laboratories that have to document a limited body voltage.

Position within the range: Mipolam Biocontrol EL5 carries the same cleanroom qualification but limits body voltage to 100 V and offers four colours instead of one.

Price and availability on request. We calculate quantity, waste allowance, welding rod and accessories for your project: send an enquiry.