Mipolam Biocontrol ESD+

Mipolam Biocontrol ESD+ is the covering for cases where the usual 100 V body voltage limit is not enough. To IEC 61340-4-5 and ANSI/ESD STM 97.2 the charge stays below 35 V. The homogeneous vinyl is 2 mm thick, supplied as a 200 cm x 20 m roll, and is suitable for cleanrooms. Measured in the laboratory, resistance to ground is below 106 Ω; the normative figure to IEC 61340-5-1 and ANSI/ESD S20.20 is below 109 Ω.

Price and availability on request. We calculate quantity, waste allowance, welding rod and accessories for your project: send an enquiry.

Advantages

Key technical features

The key technical properties at a glance.

⚡ Body voltage below 35 V - to IEC 61340-4-5 and ANSI/ESD STM 97.2, measured with ESD footwear to S20.20 and IEC 61340-5-1
✓ Conductive, Rg ≤ 106 Ω to EN 1081 and EN 14041 - laboratory measurements to IEC 61340-4-1 and ANSI/ESD STM 7.1 put Rgp and Rpp below 106 Ω
✦ Suitable for cleanrooms - same product family as Biocontrol EL5, Evercare™ surface treatment, antibacterial and antiviral tested
↕ Roll 200 cm x 20 m, 2.0 mm, 2980 g/m² - homogeneous type I build, impact sound reduction 5 dB
📦 Colour 1000 Graphite - NCS 4005-R80B, LRV 29.7, the dark shade keeps marks discreet in high security areas
⚙ Use class 34 - 43, Bfl-s1, R9 - highest commercial and industrial class to EN ISO 10874

In detail

Technical data as per manufacturer data sheet

The key data in table form.

PropertyStandardValue
Overall thicknessEN ISO 243462,0 mm
Weight per areaEN ISO 239972980 g/m²
Roll widthEN ISO 24341200 cm
Roll lengthEN ISO 2434120 m
Installation method-fully bonded
Binder contentEN ISO 10581Typ I
Product standard-EN ISO 10581
European classificationEN ISO 1087434 - 43
Reaction to fireEN 13501-1Bfl-s1
Electrical resistanceEN 1081 / EN 14041Rg ≤ 106
Electrical resistanceIEC 61340-4-1 / IEC 61340-5-1Rgp < 109 (normativ), Rgp < 106 (Labor)
Electrical resistanceANSI/ESD STM 7.1 / S20.20Rgp und Rpp < 109 (normativ), < 106 (Labor)
Body voltage generationEN 1815< 2 kV
Body voltage generationIEC 61340-4-5 / ANSI/ESD STM 97.2< 35 V
ESD protectionIEC 61340-5-1 / ANSI/ESD S20.20compliant
Slip resistanceDIN 51130R9
Impact sound reductionEN ISO 717-25 dB
Dimensional stabilityEN ISO 23999≤ 0,4 %
Residual indentationEN ISO 24343-1≤ 0,1 mm
Castor chair suitabilityISO 4918yes, type W
Thermal conductivityEN ISO 104560,25 W/(m·K)
Colour fastness to lightEN ISO 105-B02≥ 6
Surface treatment-Evercare™
Antibacterial activityISO 22196> 99 % growth inhibition
Antiviral activityISO 2170299.7 % after 2 h, 99.9 % after 5 h
Chemical resistanceEN ISO 26987very good resistance
TVOC after 28 daysISO 16000-6< 10 µg/m³
Certificate-FloorScore™
CE markingEN 14041compliant

Complete values including test conditions are given in the Mipolam Biocontrol ESD+ data sheet available for download in this category. Resistance values are measured before installation.

In detail

Colours and article numbers

The key data in table form.

ColourArticle numberNCSLRV
1000 Graphite8667-10004005-R80B29,7
  • The LRV values (light reflectance value) support lighting and contrast planning
  • the NCS notation helps to match wall and furniture colours

Applications

Typical applications

Where these products are typically used.

  • manufacturing and testing of highly sensitive class 0 devices to ANSI/ESD S20.20
  • semiconductor back end and wafer handling
  • cleanrooms with combined ESD and particle requirements
  • aerospace and medical device production
  • and test laboratories that have to document a limited body voltage

Position within the range: Mipolam Biocontrol EL5 carries the same cleanroom qualification but limits body voltage to 100 V and offers four colours instead of one.

FAQ

Frequently asked questions about Mipolam Biocontrol ESD+