Recalibration of the resistance decade box with traceable ISO9000 certificate - Iteco 9264982

This item is a service, not a device. Iteco recalibrates your existing calibration decade box 9264.980 or 9264.981 and supplies a traceable ISO9000 calibration report with it. Your test equipment records stay complete.

Net
€59.36
excl. VAT
Item ITC-9264982
Manufacturer no. 9264982
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

A calibration device is only worth as much as its own evidence. This order item therefore contains no hardware, it covers the recalibration of an Iteco resistance decade box you already own. The unit is checked by the manufacturer and returns with a traceable ISO 9000 calibration report documenting the ±1 % tolerance.

What you receive

  • Traceable ISO 9000 calibration report for the resistance decade box you send in
  • Verification of the resistance values against the ±1 % tolerance stated by the manufacturer
  • An unbroken chain of test equipment, because the reference used for the annual verification of your test stations is itself documented
  • A document that answers the audit question about traceability of the calibration device
  • No hardware in the delivery, the item always refers to an existing unit

Scope of the service

When to order this item

  • Before internal and customer audits where traceability has to be shown
  • After the calibration interval defined in your quality system has expired
  • After transport damage, a drop or a repair of the decade box
  • When a second-hand unit is added to a test equipment register

Process and delimitation

The decade box is sent in, measured at the manufacturer and returned together with the calibration report. Other Iteco instruments have their own recalibration items, for example the Test Station EVO, the GigaLab, the Walking Test EVO or the Charger EVO. If you do not own a decade box yet, order unit 9264.980 or 9264.981 first, as the initial calibration evidence is already supplied with it.

Standard and execution

The calibration report is traceable to ISO 9000. The calibration procedures for which the device is used in service follow IEC 61340-5-1. The recalibration is carried out by the manufacturer Iteco Trading in Italy.

Technical data

FeatureDetail
Type of itemservice with a document, not a device purchase
Resulttraceable ISO9000 calibration report
Suitable forIteco resistance decade box 9264.980 with 110 MΩ and 9264.981 with 2 GΩ
Verified tolerance±1 %
Application standard of the deviceIEC 61340-5-1
Scope of supplycalibration report for the unit sent in, no hardware
Order quantityone item per unit to be calibrated
Weight1.000000
ManufacturerIteco
Manufacturer Nr.9264982
GPSR manufacturer informationIteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it
Sales unitStück
ESD versionESD (antistatic)
NormDIN EN ISO 9000
CertificationIEC 61340-5-1

Downloads