How to set up a break room that meets ASR A4.2?

A break room becomes mandatory above certain headcounts and must follow clear rules. This guide explains what ArbStättV and ASR A4.2 require for floor area, seating, a kitchenette and equipment, and how to plan the room in practice.

5 minStand: 2026-07Geprüft: Technical editors
View workplace equipment
> 10
Employees: break room required
1 m²
Area per simultaneous user
6 m²
Minimum room floor area
Backrest
Seat with backrest per person
Inhalt
  1. Requirement and basics
  2. Area and seating
  3. Kitchenette and equipment
  4. Frequently asked questions

When is a break room mandatory?

Under the German Workplace Ordinance (ArbStättV) and the implementing rule ASR A4.2, a break room or break area must be provided where more than ten employees work, or wherever safety and health demand it, for example during demanding tasks. The room offers undisturbed recovery away from the workstation.

Regardless of headcount, a dedicated break room is always required when burdens such as noise, dirt, wetness or hazardous substances would persist during the break. Staff with mainly seated or standing work must be able to sit down and set aside their work clothing.

A break area is sufficient in businesses with no more than ten employees. It must be physically separated from the workstation and must not sit in a traffic route or the immediate production zone.
Plan your workplace

Equip break room, workshop and storage to standard.

Read the guide

How much area and how many seats?

ASR A4.2 specifies a floor area of at least 1 m² per simultaneously present employee, including tables and seating. The total area of the break room should not fall below 6 m². Clear headroom follows ASR A1.2 and is at least 2.50 m depending on room size.

The maximum number of people present during the busiest break is decisive, not the total workforce. Each person needs a seat with a backrest and table space. This makes the area requirement straightforward to plan.

Allow movement space between tables of at least 0.80 m so occupied chairs do not block passage.

What equipment does the break room need?

Basic equipment includes tables, seating with backrests and a way to heat and store food and drinks. A kitchenette with a sink, fridge and microwave meets this requirement in practice. Drinking water or a beverage supply should be within reach.

  • Kitchenette with sink, hot and cold water and adequate worktop.
  • Refrigerator for storing food brought from home.
  • Microwave or heating option for warming meals.
  • Tables and chairs with backrests for every simultaneous user.
  • Coat hooks or a wardrobe for work clothing, kept away from food.
  • Adequate lighting and a clock to keep track of break time.

The break room must be heatable and allow a room temperature of at least 21 °C. A visual connection to the outside and sufficient ventilation raise the recovery value. Production noise should not reach the room, and a rating level below 55 dB(A) is the target.

In non-smoking workplaces, protection from tobacco smoke under ArbStättV is mandatory. A break room must not double as a passageway or storage space.

Frequently asked questions

From how many employees is a break room mandatory?

Under ASR A4.2 a break room must be provided above ten employees. Where conditions are demanding, such as noise or hazardous substances, it is required regardless of headcount.

How large must the break room be?

At least 1 m² per simultaneously present employee and a minimum floor area of 6 m² apply. The busiest simultaneous occupancy is decisive, not the total workforce.

Is a kitchenette required?

ASR A4.2 requires a way to heat and store food and drinks. A kitchenette with sink, fridge and microwave meets this requirement in practice.

What temperature must the break room reach?

The room must be heatable and reach at least 21 °C. Sufficient ventilation and protection from production noise are also required.

Set up a compliant break room?

We supply tables, chairs, kitchenette modules and lockers for staff rooms to ArbStättV and ASR A4.2 - complete and from a single source.

Standard-compliant

Equipment matched to ArbStättV and ASR A4.2.

Complete

From table and chair to kitchenette and locker.

Robust

Durable furniture for daily operation.

Expert advice

We plan the staff room around your occupancy.

More guides