Resistance decade box 10 Ω to 110 MΩ for the calibration of ESD testers - Iteco 9264980
-
This Item:
€339.96
-
Calibration unit for two-point probe from Mini Probe Set 840 - Warmbier 7220.844.C
€75.04
-
Calibration TF-530 thermo-hygrometer incl. certificate - Warmbier 7100.TF530.KA
€92.11
Anyone running wrist strap and footwear testers to IEC 61340-5-1 has to verify their switching thresholds at regular intervals. The resistance decade box 9264.980 applies defined resistances from 10 Ω to 110 MΩ with a tolerance of ±1 % to the test input and shows whether a tester still decides correctly.
Benefits for test equipment control
- Resolution of 10 Ω across the whole range, so the lower thresholds of personnel testing can be approached precisely
- ±1 % resistor tolerance, considerably tighter than the pass limits of the test stations themselves
- Rated 1 W up to 4 MΩ and 0.5 W from 10 MΩ to 40 MΩ, matched to the test voltages of the testers
- Operating voltage up to 250 V AC, so instruments with higher test voltage can be connected as well
- Compact 320 g in a 147 x 117 x 55 mm housing, fits into any tool or test equipment case
- Cables and adapters are included, together with a detailed manual on the calibration procedures of IEC 61340-5-1
Technical data
| Feature | Value |
|---|---|
| Range | 10 Ω to 110 MΩ |
| Resolution | 10 Ω |
| Tolerance | ±1 % |
| Rating up to 4 MΩ | 1 W |
| Rating 10 MΩ to 40 MΩ | 0.5 W |
| Operating voltage | 250 V AC max |
| Dimensions | 147 x 117 x 55 mm |
| Weight | 320 g |
| Scope of supply | decade box, cables, adapters, manual |
| Reference standard | IEC 61340-5-1 |
Applications
- Annual or half-yearly in-house verification of test stations
- Incoming inspection of newly purchased testers before release for the EPA
- Troubleshooting when a test station rejects or passes an unusual number of people
- Evidence for auditors that the pass limits of the testers are being checked
- Training of ESD coordinators on defined resistance values
Compatibility and scope of supply
The decade box is built for calibrating the ESD test stations Wristlab-II, Test Station EVO and Wristlab PRO as well as other testers working to IEC 61340-5-1. Cables and measuring adapters are included. If the range is not sufficient because values in the gigaohm region are required, version 9264.981 covers up to 2 GΩ. Recalibration of the decade box itself is available as separate item 9264.982 with a traceable ISO9000 certificate.
Standards and origin
The supplied manual describes the calibration procedures of IEC 61340-5-1. Manufactured by Iteco Trading in Italy.
| Norm | DIN EN ISO 9000 |
|---|---|
| Certification | IEC 61340-5-1 |
| ESD version | ESD (antistatic) |
| Manufacturer Nr. | 9264980 |
| Manufacturer | Iteco |
| Country of Manufacture | Italy |
| Weight | 0.320000 |
| Height | 55 |
| Width | 147 |
| Depth | 117 |
| Sales unit | Stück |
| GPSR manufacturer information | Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it |