Images are for illustration purposes only and may differ from the actual product. Some images have been generated or edited, in whole or in part, using artificial intelligence systems. The technical specifications in the product description are authoritative.
ATEX compliant wall version of the Wristlab II personnel test station. The footwear high limit is fixed at 1 GΩ instead of the selectable 10 to 200 MΩ of the standard model, while the wrist strap is still checked against 750 kΩ to 35 MΩ.

ESD Personnel Test Station Wristlab II ATEX 1 GΩ wall mounted complete - Iteco 9264950.1G

ITECO Original product
Net price (excl. VAT)
€300.72
Item ITC-92649501G
Manufacturer no. 9264950.1G
ESD · IEC 61340-5-1 ATEX
Personal expert advice
Brand new Specialist dealer since 2009 Original product Worldwide shipping
Product data
Manufacturer no.9264950.1G
Country of originItaly
Article
ITC-92649501G
Frequently Bought Together
Total price

In potentially explosive atmospheres footwear is judged against a different limit than in a classic EPA. The Wristlab II 9264.950.1G is built for exactly that case: it is the ATEX compliant wall version of the personnel test station and measures the dissipative resistance of the shoes against a fixed upper limit of 1 GΩ.

Difference to the standard 9264.950

  • Footwear high limit fixed at 1 GΩ, no switching to 10 to 200 MΩ
  • High resistance ATEX rated soles are therefore rated as pass
  • Wrist strap test unchanged at 750 kΩ to 35 MΩ to IEC 61340-5-1
  • Left and right shoe measured separately at 50 V or 100 V
  • Relay contact for releasing access to the EPA

Four operating modes

  • Simultaneous measurement of wrist strap and footwear in a single test
  • Wrist strap only, for operators seated at the workstation
  • Footwear only, for visitors without a wrist strap
  • HandsFree: if both shoes pass the series measurement, the internal relay switches and releases the access gate to the EPA

Technical data

Test standardIEC 61340-5-1
Items testedWrist strap and footwear, left and right shoe measured separately
Test voltage50 V or 100 V, selectable
Wrist strap limitslow limit 750 kΩ / high limit 35 MΩ
Footwear low limit0 to 100 kΩ, selectable
Footwear high limit1 GΩ fixed, ATEX compliant version
Operating modes4 (wrist strap and footwear together, wrist strap only, footwear only, HandsFree)
Outputrelay contact for releasing access to the EPA
Power supplyinternal 9 V battery or external 9 V DC
Instrument dimensions156 x 110 x 34 mm
Instrument weight340 g
CalibrationISO 9000 traceable calibration report included
Mountingwall mounting
Scope of deliveryWristlab-II instrument in ATEX version, footplate, yellow instruction panel, calibration report
Panel languageEnglish
OriginItaly

Applications

Access control to areas where an explosive atmosphere has to be considered next to the ESD requirement, for example in paint processing, in chemical plants or in the assembly of pyrotechnic devices.

Accessories and compatibility

The stand 9264.953 and the dual footplate 9264.965 fit without changes. If only the instrument is needed in the ATEX version it is available separately as 9264.960.1G. Recalibration is covered by 9264.955.

The order code is completed with a language letter (I, F, E, D, H, S). This version is supplied with the English instruction panel.

Made in Italy by Iteco, with an ISO 9000 traceable calibration report.

More Information
Norm DIN EN ISO 9000
Certification ATEX, IEC 61340-5-1
ESD version ESD (antistatic)
Manufacturer Nr. 9264950.1G
Manufacturer Iteco
Country of Manufacture Italy
Weight 1.000000
Sales unit Stück
GPSR manufacturer information Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it
Series Wristlab II
Operating voltage 9 V