Images are for illustration purposes only and may differ from the actual product. Some images have been generated or edited, in whole or in part, using artificial intelligence systems. The technical specifications in the product description are authoritative.
Free standing personnel test station with column, footplate and instruction panel. It checks the wrist strap and both shoes separately to IEC 61340-5-1 at 50 or 100 V and needs no wall surface at the EPA entrance.

ESD Personnel Test Station Wristlab II stand-up complete with footplate - Iteco 9264952

ITECO Original product
Net price (excl. VAT)
€411.04
Item ITC-9264952
Manufacturer no. 9264952
ESD · IEC 61340-5-1
Personal expert advice
Brand new Specialist dealer since 2009 Original product Worldwide shipping
Product data
Manufacturer no.9264952
Country of originItaly
Article
ITC-9264952
Frequently Bought Together

Not every EPA entrance offers a free wall. The Wristlab II 9264.952 is therefore the version on a stand-up column: instrument, footplate for the shoe test and the yellow instruction panel are mounted on their own support and can be placed exactly where people actually walk in.

What this version offers

  • Fully assembled station, no drilling into a wall or a partition
  • Wrist strap and footwear tested to IEC 61340-5-1 in a single operation
  • Left and right shoe measured separately at 50 V or 100 V
  • Wrist strap window 750 kΩ to 35 MΩ, footwear upper limit selectable from 10 MΩ to 200 MΩ
  • Relay contact for a turnstile or a door opener, so the station can act as access control
  • Powered by a 9 V battery or an external 9 V DC supply

Four operating modes

  • Simultaneous measurement of wrist strap and footwear in a single test
  • Wrist strap only, for operators seated at the workstation
  • Footwear only, for visitors without a wrist strap
  • HandsFree: if both shoes pass the series measurement, the internal relay switches and releases the access gate to the EPA

Technical data

Test standardIEC 61340-5-1
Items testedWrist strap and footwear, left and right shoe measured separately
Test voltage50 V or 100 V, selectable
Wrist strap limitslow limit 750 kΩ / high limit 35 MΩ
Footwear low limit0 to 100 kΩ, selectable
Footwear high limit10 MΩ / 35 MΩ / 70 MΩ / 100 MΩ / 200 MΩ, selectable
Operating modes4 (wrist strap and footwear together, wrist strap only, footwear only, HandsFree)
Outputrelay contact for releasing access to the EPA
Power supplyinternal 9 V battery or external 9 V DC
Instrument dimensions156 x 110 x 34 mm
Instrument weight340 g
CalibrationISO 9000 traceable calibration report included
Mountingfree standing on a column support
Scope of deliveryWristlab-II instrument, footplate, yellow instruction panel, stand-up support, calibration report
Panel languageEnglish
OriginItaly

Applications

In front of cleanroom and EPA airlocks, in open plan production halls and wherever the test point has to move when the layout changes. Combined with the turnstile 9266.100 it becomes an access control that opens only after a passed measurement.

Accessories and compatibility

The dual footplate 9264.965 replaces the standard footplate and certificate 9264.955 covers recalibration. If only the column is required to upgrade an existing wall station it is listed separately as 9264.953.

The order code is completed with a language letter (I, F, E, D, H, S). This version is supplied with the English instruction panel.

Made in Italy by Iteco, with an ISO 9000 traceable calibration report.

More Information
Norm DIN EN ISO 9000
Certification IEC 61340-5-1
ESD version ESD (antistatic)
Manufacturer Nr. 9264952
Manufacturer Iteco
Country of Manufacture Italy
Weight 1.000000
Sales unit Stück
GPSR manufacturer information Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it
Series Wristlab II
Operating voltage 9 V
Position sensing No
Accessories from our range
ESD version