ESD Personnel Test Station Wristlab II stand-up complete with footplate - Iteco 9264952
-
This Item:
€411.04
-
Calibration unit with 12 DIP switches for PGT 120 personnel tester - Warmbier 7100.PGT120.CU.12
€107.29
-
Wall Mounting Plate for Safe-STAT Combi-Meter
€58.88
Not every EPA entrance offers a free wall. The Wristlab II 9264.952 is therefore the version on a stand-up column: instrument, footplate for the shoe test and the yellow instruction panel are mounted on their own support and can be placed exactly where people actually walk in.
What this version offers
- Fully assembled station, no drilling into a wall or a partition
- Wrist strap and footwear tested to IEC 61340-5-1 in a single operation
- Left and right shoe measured separately at 50 V or 100 V
- Wrist strap window 750 kΩ to 35 MΩ, footwear upper limit selectable from 10 MΩ to 200 MΩ
- Relay contact for a turnstile or a door opener, so the station can act as access control
- Powered by a 9 V battery or an external 9 V DC supply
Four operating modes
- Simultaneous measurement of wrist strap and footwear in a single test
- Wrist strap only, for operators seated at the workstation
- Footwear only, for visitors without a wrist strap
- HandsFree: if both shoes pass the series measurement, the internal relay switches and releases the access gate to the EPA
Technical data
| Test standard | IEC 61340-5-1 |
|---|---|
| Items tested | Wrist strap and footwear, left and right shoe measured separately |
| Test voltage | 50 V or 100 V, selectable |
| Wrist strap limits | low limit 750 kΩ / high limit 35 MΩ |
| Footwear low limit | 0 to 100 kΩ, selectable |
| Footwear high limit | 10 MΩ / 35 MΩ / 70 MΩ / 100 MΩ / 200 MΩ, selectable |
| Operating modes | 4 (wrist strap and footwear together, wrist strap only, footwear only, HandsFree) |
| Output | relay contact for releasing access to the EPA |
| Power supply | internal 9 V battery or external 9 V DC |
| Instrument dimensions | 156 x 110 x 34 mm |
| Instrument weight | 340 g |
| Calibration | ISO 9000 traceable calibration report included |
| Mounting | free standing on a column support |
| Scope of delivery | Wristlab-II instrument, footplate, yellow instruction panel, stand-up support, calibration report |
| Panel language | English |
| Origin | Italy |
Applications
In front of cleanroom and EPA airlocks, in open plan production halls and wherever the test point has to move when the layout changes. Combined with the turnstile 9266.100 it becomes an access control that opens only after a passed measurement.
Accessories and compatibility
The dual footplate 9264.965 replaces the standard footplate and certificate 9264.955 covers recalibration. If only the column is required to upgrade an existing wall station it is listed separately as 9264.953.
The order code is completed with a language letter (I, F, E, D, H, S). This version is supplied with the English instruction panel.
Made in Italy by Iteco, with an ISO 9000 traceable calibration report.
| Norm | DIN EN ISO 9000 |
|---|---|
| Certification | IEC 61340-5-1 |
| ESD version | ESD (antistatic) |
| Manufacturer Nr. | 9264952 |
| Manufacturer | Iteco |
| Country of Manufacture | Italy |
| Weight | 1.000000 |
| Sales unit | Stück |
| GPSR manufacturer information | Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it |
| Series | Wristlab II |
| Operating voltage | 9 V |
| Position sensing | No |