Recalibration with traceable ISO9000 certificate for WristLab - Iteco 9265031
-
This Item:
€59.36
-
FET transistors replacement for ESD demo board, pack of 20
€3.20
-
Recalibration of the resistance decade box with traceable ISO9000 certificate - Iteco 9264982
€59.36
A personnel tester is only worth as much as the proof that it still measures correctly. This item covers the recalibration of a WristLab test station and supplies a traceable ISO9000 calibration report, which serves as evidence of the verified condition of the instrument during an ESD audit. One calibration is ordered per instrument.
What this item provides
- Traceable ISO9000 report - the document is part of the delivery and is the evidence towards customers and auditors.
- Check against known resistance values - the measuring chain of the tester is compared with defined reference values.
- Linked to personnel testing to IEC 61340-5-1 - the calibration procedures for this instrument family are aligned with that standard.
- One number per instrument family - Iteco lists separate items for Test Station EVO and WristLab II so that the correct procedure is applied.
- Plannable interval - the recalibration is ordered as its own line item and can therefore be tied to the maintenance schedule.
Technical data
| Iteco part number | 9265.031 |
|---|---|
| Type of service | recalibration of one test instrument |
| Scope | WristLab personnel test stations |
| Document | traceable ISO9000 calibration report |
| Reference values | defined resistance values of a resistance decade box |
| Reference standard of the test | IEC 61340-5-1 |
| Procedure | send in the instrument, recalibration, return with certificate |
| Extent | 1 instrument per item |
| Sales unit | 1 piece |
| Manufacturer | Iteco, Italy |
Applications
Annual control of test equipment in electronics manufacturing, preparation for customer and certification audits, and returning a tester to service after its readings became suspect during in house checks.
Assignment and delimitation
The 2026 price list assigns this item to the WristLab family. Part number 9264.927 applies to the Test Station EVO, 9264.955 to WristLab II and 9264.982 to the calibration unit itself. For own checks between two recalibrations, the calibration units 9264.980 with a range up to 110 Mohm and 9264.981 with a range up to 2 Gohm are used, both with a tolerance of 1 percent.
Standards and origin
The calibration report is traceable to ISO9000 and the test procedures for ESD personnel testers refer to IEC 61340-5-1. The service is provided by the manufacturer Iteco in Italy.
| Norm | DIN EN ISO 9000 |
|---|---|
| Certification | IEC 61340-5-1 |
| ESD version | ESD (antistatic) |
| Manufacturer Nr. | 9265031 |
| Manufacturer | Iteco |
| Country of Manufacture | Italy |
| Weight | 1.000000 |
| Sales unit | Stück |
| GPSR manufacturer information | Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it |
| Series | WristLab |