Electrostatic field meter FieldLab EVO with 9 V battery and 2-LED distance guide - Iteco 9265701

Iteco Made in Italy

The FieldLab EVO reads strength and polarity of electrostatic fields in three ranges up to 20 kV, resolving 1 V in the finest range. Two LED beams converge at the specified distance of 25.4 mm and keep readings repeatable. Battery and calibration report are included.

Net
€946.68
excl. VAT
Item ITC-9265701
Manufacturer no. 9265701
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

You cannot see the charge on a bag or a fixture. The FieldLab EVO measures it in three ranges up to 20 kV and still resolves 1 V in the lowest range up to 200 V, so an item is not merely classified as charged or clean but rated with a figure.

Benefits in daily measurement

  • Three ranges of 20 kV, 1.5 kV and 200 V cover everything from a heavily charged plastic bag to a weak residual charge with one meter
  • Resolution of 100 V, 10 V and 1 V matched to each range instead of one coarse scale across the whole span
  • Two LED beams converge at 25.4 mm and mark the reference distance to which the 20 kV maximum range refers
  • Accuracy of ±10 % across the whole span, sufficient for assessment against your own ESD control plan
  • Magnitude and sign on the display, which makes charge separation between material pairings traceable
  • One-handed use with a 9 V battery and a grounding lead with clip for a defined reference to the earth bonding system

Applications

  • Assessment of packaging material, films and containers at incoming inspection
  • Checking populated boards and assemblies along the production line
  • Verifying ionized areas and workstations for remaining field strength
  • Tracing insulating disturbance sources when sensitive parts fail repeatedly
  • Training and demonstration, because charge build-up can be shown as a number

Compatibility and scope of supply

Supplied with the meter, the insulated metal plate for ion balance mode, a grounding lead with clip, the 9 V battery and the traceable calibration report. Combined with the Charger EVO, which charges insulated plates from 100 to 1100 V in 1 V steps, the discharge time of an ioniser also becomes measurable. The FIELDLAB version 9265.501 instead offers ±5 % accuracy and an analogue output for recording devices. The meter complements resistance measurement with the GigaLab EVO and personnel testing with the Walking Test EVO in the ESD Survey Kit.

Origin

Manufactured by Iteco Trading in Italy.

Technical data

FeatureValue
Coarse range±20 kV, resolution 100 V
Medium range±1.5 kV, resolution 10 V
Fine range±200 V, resolution 1 V
Accuracy±10 %
Reference distance for the maximum range25.4 mm, equal to 1 inch
Distance aidtwo LED beams converging at the correct distance
Additional functionion balance mode with the insulated metal plate supplied
Displayed valuesfield strength and polarity
Power supply9 V battery, included
Calibrationtraceable ISO9000 calibration report included
Weight1 kg
ManufacturerIteco
Manufacturer Nr.9265701
GPSR manufacturer informationIteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it
Country of ManufactureItaly
Sales unitStück
ESD versionESD (antistatic)
NormDIN EN ISO 9000
CertificationIEC 61340-5-1
Operating voltage9 V
SeriesFieldLab EVO

Downloads