Images are examples, some edited with AI. The technical data are authoritative. AI notice
FieldLab model 775 electrostatic field meter up to ±20 kV - Iteco 9265501
The FieldLab 775 measures the strength and polarity of electrostatic fields up to ±20 kV with ±5 % accuracy. Two LED beams secure the 25.4 mm measuring distance and an analogue output allows recording. A 9 V battery and calibration report are included.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Charged packaging, carriers and badly balanced ionisers only show up in a field measurement. The FieldLab model 775 detects the strength and polarity of electrostatic fields up to ±20 kV at a defined measuring distance of 25.4 mm with an accuracy of ±5 %.
Benefits
- Three ranges of ±20 kV, ±1.5 kV and ±200 V with 100 V, 10 V and 1 V resolution cover everything from packaging checks to residual voltage readings.
- Two LED beams converge exactly at the correct distance of 25.4 mm, which removes the most common source of error.
- Accuracy of ±5 % keeps the model 775 tighter than the FieldLab EVO with ±10 %.
- The ion balance mode verifies ionisers using the supplied insulated metal plate.
- The analogue output lets the field curve be recorded on an external device.
- An ISO 9000 traceable calibration report is supplied with the instrument.
Applications
Incoming inspection of packaging material, checks on assemblies and workpiece carriers, verification of ionisers and ionised zones and tracing charged plastic parts on assembly lines.
Standards and origin
Field measurement is part of the compliance verification within the ESD control programme to IEC 61340-5-1.
Technical data
| Measuring range | ±20 kV, ±1.5 kV and ±200 V |
|---|---|
| Resolution | 100 V, 10 V and 1 V depending on range |
| Accuracy | ±5 % |
| Measuring distance | 25.4 mm, guided by two LED beams |
| Ion balance mode | with the supplied insulated metal plate |
| Analogue output | for an external recording device |
| Power supply | 9 V battery, included |
| Calibration report | ISO 9000 traceable, included |
| Model designation | 775 |
| Manufacturer number | 9265.501 |
| Weight | 1 kg |
| Manufacturer | Iteco |
| Manufacturer Nr. | 9265501 |
| GPSR manufacturer information | Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it |
| Country of Manufacture | Italy |
| Sales unit | Stück |
| ESD version | ESD (antistatic) |
| Norm | DIN EN ISO 9000 |
| Certification | IEC 61340-5-1 |
| Operating voltage | 9 V |
| Series | FieldLab |
Scope of delivery
Delivery includes the field meter, the insulated metal plate for ion balance mode, a 9 V battery and the calibration report. Decay time measurements on ionisers additionally require the Charger EVO plate charger Iteco 9265.401.
Downloads
Datasheet
Catalogue
Accessories
Walking Test EVO body voltage measuring system with probe and case - Iteco 9265080
Item ITC-9265080FieldLab EVO field meter up to 20 kV with ion balance mode and 9 V battery - Iteco 9265700
Item ITC-9265700Electrostatic field meter FieldLab EVO with 9 V battery and 2-LED distance guide - Iteco 9265701
Item ITC-9265701Ioniser verification system with Charger EVO, field meter not included - Iteco 9265505
Item ITC-9265505Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.