Images are examples, some edited with AI. The technical data are authoritative. AI notice
Resistance decade box 10 Ω to 2 GΩ for the calibration of ESD testers - Iteco 9264981
The large version of the Iteco calibration decade reaches 2 GΩ, around eighteen times higher than the 110 MΩ model. It therefore also covers test stations whose upper pass limit sits in the gigaohm region. Tolerance ±1 %, cables and adapters included.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Test stations judge not only the lower but also the upper resistance limit of personnel grounding. Where that limit sits in the gigaohm region, a decade box ending at 110 MΩ can no longer reach it. Version 9264.981 goes up to 2 GΩ and thus covers the complete assessment range of current testers with a tolerance of ±1 %.
What the large version offers
- Upper limit of 2 GΩ instead of 110 MΩ, so the upper switching thresholds of personnel and footwear testing are reached
- Resolution of 100 Ω, matched to the extended span of the decade box
- Resistor tolerance of ±1 % across the whole range, which keeps the tester and not the reference the source of any deviation
- Rated 1 W up to 4 MΩ and 0.5 W from 10 MΩ to 40 MΩ, operating voltage up to 250 V AC
- Same compact housing as the smaller model with 147 x 117 x 55 mm and 320 g, so handling in the field is unchanged
- Cables, adapters and the detailed manual on the calibration procedures of IEC 61340-5-1 are included
Applications
- Calibration of test stations whose upper pass limit lies above 110 MΩ
- Verification of Wristlab PRO installations with an extended measuring span
- Central test equipment control at sites running different tester generations
- Investigating borderline cases where people repeatedly fail by a small margin
- Service providers and auditors who want to cover several customer installations with one reference
Compatibility and scope of supply
The decade box is intended for Wristlab-II, Test Station EVO, Wristlab PRO and other testers working to IEC 61340-5-1. Cables and measuring adapters are included. If only the range up to 110 MΩ is needed, version 9264.980 is the more economical choice. Recalibration of this decade box is ordered as separate item 9264.982 with a traceable ISO9000 certificate.
Standards and origin
The supplied manual describes the calibration procedures of IEC 61340-5-1. Manufactured by Iteco Trading in Italy.
Technical data
| Feature | Value |
|---|---|
| Range | 10 Ω to 2 GΩ |
| Resolution | 100 Ω |
| Tolerance | ±1 % |
| Rating up to 4 MΩ | 1 W |
| Rating 10 MΩ to 40 MΩ | 0.5 W |
| Operating voltage | 250 V AC max |
| Dimensions | 147 x 117 x 55 mm |
| Weight | 320 g |
| Scope of supply | decade box, cables, adapters, manual |
| Reference standard | IEC 61340-5-1 |
| Manufacturer | Iteco |
| Manufacturer Nr. | 9264981 |
| GPSR manufacturer information | Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it |
| Country of Manufacture | Italy |
| Sales unit | Stück |
| Height | 55 |
| Width | 147 |
| Depth | 117 |
| ESD version | ESD (antistatic) |
| Norm | DIN EN ISO 9000 |
| Certification | IEC 61340-5-1 |
Downloads
Datasheet
Catalogue
Accessories
Resistance decade box 10 Ω to 110 MΩ for the calibration of ESD testers - Iteco 9264980
Item ITC-9264980WristLab Pro personnel test station wall mounted standard version - Iteco 9264971
Item ITC-9264971ESD Personnel Test Station Wristlab II stand-up complete with footplate - Iteco 9264952
Item ITC-9264952ESD Personnel Test Station Wristlab II wall mounted complete with footplate - Iteco 9264950
Item ITC-9264950ESD personnel tester Test Station EVO Ethernet with fingerprint recognition, instrument only - Iteco 9264926
Item ITC-9264926ESD personnel tester Test Station EVO USB with fingerprint recognition, instrument only - Iteco 9264925
Item ITC-9264925WristLab Pro grounding tester standard version 50 kΩ to 2 GΩ - Iteco 9264990
Item ITC-9264990Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.