ISO9000 traceable recalibration certificate for Test Station EVO - Iteco 9264927

Iteco Made in Italy

Recalibration of a Test Station EVO personnel tester including an ISO9000 traceable calibration report. The resistance measurement from 50 kΩ to 2 GΩ and the test voltages 50 V and 100 V are verified. The certificate applies per instrument.

Net
€145.43
excl. VAT
Item ITC-9264927
Manufacturer no. 9264927
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

An ESD personnel tester is only worth as much as the proof that it still measures correctly. This item covers the recalibration of one Test Station EVO instrument at the manufacturer together with the matching ISO9000 traceable calibration report on the resistance measurement in the range 50 kΩ to 2 GΩ.

Benefits in daily EPA operation

  • Traceable calibration report that auditors and customers accept as evidence of test equipment control
  • Verification of the resistance measurement for wrist strap and footwear across the full 50 kΩ to 2 GΩ range
  • Check of both test voltages 50 V and 100 V as well as the measuring accuracy of ±10 %
  • Reference to IEC 61340-5-1, the standard the EPA is operated and audited against
  • Valid for every version of the series, from the USB wall model to the RFID-PLUS version

Applications

Recalibration belongs in the test equipment control programme of every EPA and is usually commissioned once a year. It is ordered together with the instrument or later as a separate service when the calibration interval expires.

Compatibility and scope of delivery

Charged per instrument. Anyone who wants to check basic function between two calibrations uses the resistance decade boxes Iteco 9264980 up to 110 MΩ or Iteco 9264981 up to 2 GΩ with a tolerance of ±1 %.

Standards and origin

The reference standard is IEC 61340-5-1 and the calibration values are ISO9000 traceable. The service is carried out at the manufacturer in Italy.

Technical data

ServiceRecalibration of one Test Station EVO instrument
DocumentationCalibration report with ISO9000 traceable values
Verified quantitiesResistance measurement of wrist strap and footwear
Verified measuring range50 kΩ - 2 GΩ
Verified test voltages50 V and 100 V
Reference accuracy±10 %
Reference standardIEC 61340-5-1
Applicable toTest Station EVO 9264.920, 9264.921, 9264.922, 9264.923, 9264.925, 9264.926, 9264.929, 9264.929M, 9264.929P
Unit of sale1 certificate per instrument
OriginItaly
Weight1 kg
ManufacturerIteco
Manufacturer Nr.9264927
GPSR manufacturer informationIteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it
Country of ManufactureItaly
Sales unitStück
ESD versionESD (antistatic)
NormDIN EN ISO 9000
CertificationIEC 61340-5-1
SeriesTest Station EVO