Images are examples, some edited with AI. The technical data are authoritative. AI notice
Lötrauchfiltersystem 6211 - Quick QU6211
Single bench extraction station with far more reserve than a typical desktop unit, 200 m³/h at 6000 Pa static pressure. Four filter stages up to the carbon element retain 99.97 percent at 0.3 µm, and an LCD with change reminder guides maintenance. Also intended for laser soldering and laser marking.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
With long hose runs or small nozzles, airflow collapses before it ever reaches the unit. The Quick 6211 answers that with 6000 Pa of static pressure while still moving 200 m³/h of system flow with the filters fitted, twice the air of the 100 m³/h class.
Operating benefits
- 6000 Pa static pressure, enough reserve for longer hoses, small nozzles and partly loaded filters.
- 200 m³/h system flow with filters, which also suits processes with heavy fume such as laser soldering.
- Four filter stages, pre-filter, medium filter, main filter and activated carbon filter, rated 99.97 percent at 0.3 µm.
- LCD display for operating states and settings, with airflow adjustable in several steps.
- Filter change reminder, so elements are replaced on condition rather than on a hunch.
- DB9 interface for signals and communication, with settable communication address and baud rate for integration into equipment.
- Blocked rotor alarm and language selection in the menu, so faults surface early.
Application, setup and safety notes
Intended for electronics and soldering benches, rework and service, manual soldering stations and for laser soldering, marking and engraving positions. In use the station is set up, connected to the capture point through the extraction hose and plugged in, after which airflow is stepped to suit the process. According to the manual the unit must not be used to extract flammable or explosive gases, nor in areas with open flame, very high heat or heavy sparking. It has to stand upright in operation, and air inlet and outlet must stay clear. Matching replacement filters are listed as QU6211PF, QU6211MF, QU6211HEPA and QU6211ACF.
Technical data
| Brand | Quick |
|---|---|
| Part number | QU6211 |
| Workstations | 1 |
| Operating voltage | AC 220 V |
| Power consumption | 400 W |
| System flow with filters | 200 m³/h |
| Static pressure | 6000 Pa |
| Filtration efficiency | 99.97 percent at 0.3 µm |
| Filter system | Pre-filter, medium filter, main filter, activated carbon filter |
| Noise level | 70 dB max. |
| Display | LCD |
| Interface | DB9 |
| Features | Filter change reminder, multi step airflow control, rotor alarm, language selection |
| Dimensions | 319 x 227 x 422 mm |
| Weight | approx. 10.6 kg |
| Manufacturer | Quick |
| Manufacturer Nr. | QU6211 |
| GPSR manufacturer information | Bräunlich GmbH Am Heideberg 26, DE 06886 Lutherstadt Wittenberg, www.braeunlich-gmbh.com |
| Condition of article | New |
| Article authenticity | Original product |
| Air flow [m³/h] | 200 |
| Filter class | Activated carbon |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.