Extraction cabinet CBC-A with air barrier 160 mm connection for central extraction - Weller CBCA112G02G65I2N
- This Item: €4,389.58
- Extraction hose 40 mm x 1000 mm with 2 connectors for Zero Smog 20T - Weller T0053631699 €128.96
- Flexible extraction arm Easy-Click 60 Ø 60 mm 0.5 m - Weller 0F05 €81.97
Bonding, soldering and cleaning release vapours that reach the operator as soon as the hood runs short of air flow. The CBC-A extraction cabinet solves this with a ventilation concept based on a double air barrier: the air curtain separates operator and application while the workbench stays fully accessible. A minimum of 180 m³/h is required, the maximum extracted volume is 230 m³/h.
Benefits
- Double air barrier separates operator and process with unrestricted access to the workbench
- Up to 80 % lower energy costs than a conventional extraction hood, 200 m³/h instead of around 1000 m³/h
- Large front opening without a glass pane, giving a wide and unobstructed working area
- Low noise emission of 49 dBA for continuous use at the workstation
- Interior with fluorescent lighting 2 x 39 W and 4 device sockets at 230 V
- Mobile use on a work table or trolley, connection to central extraction via a 160 mm port
Technical data
| Item number | WL34175 |
| Model | CBCA112G02G65I2 |
| Manufacturer | Weller |
| Manufacturer item number | CBCA112G02G65I2N |
| Dimensions (LxWxH) | 760 mm x 1275 mm x 625 mm |
| Voltage | 230 V |
| Frequency | 50 Hz |
| Power | 65 W |
| Noise level | 49 dBA |
| Central extraction connection | 160 mm |
| Minimum extraction volume | 180 m³/h |
| Maximum extraction volume | 230 m³/h |
| Lighting | Fluorescent tubes 2 x 39 W |
| Device sockets | 4 x 230 V |
| Alternative version | 120 V version CBCA112G02G65I2115 |
| Order unit | Piece |
| Weight | 0.1 kg |
Applications
Workstations generating vapours and aerosols in electronics manufacturing and laboratories: hand soldering and rework, bonding and potting, solvent cleaning, coating and conformal coating. The right choice wherever full enclosure would disturb the workflow but the operator still has to stay separated from the vapour.
Compatibility and scope of delivery
Scope of delivery: CBC-A extraction cabinet with air barrier, interior lighting and 4 device sockets at 230 V, designed for connection to an on-site central extraction system through a 160 mm port. Filters and an extraction unit are not included because extraction is central. For 120 V mains the variant CBCA112G02G65I2115 is available.
| Manufacturer Nr. | CBCA112G02G65I2N |
|---|---|
| Manufacturer | Weller |
| Weight | 0.100000 |
| GPSR manufacturer information | WELLER Tools GmbH Carl-Benz-Strasse 2 DE-74354 Besigheim www.weller.eu |
| Article authenticity | Original product |
| Condition of article | New |