Images are examples, some edited with AI. The technical data are authoritative. AI notice

ESD Personnel Test Station Wristlab II ATEX 1 GΩ stand-up, English panel - Iteco 9264952.1GEL

Iteco Made in Italy

Preconfigured order variant of the ATEX stand-up station Wristlab II with a fixed English instruction panel. Footwear is checked against 1 GΩ and the wrist strap against 750 kΩ to 35 MΩ to IEC 61340-5-1.

Net
€424.03
excl. VAT
Item ITC-92649521GEL
Manufacturer no. 9264952.1GEL
Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

Iteco lists the Wristlab II stations with a language letter in the order code, because the yellow panel carries the test instructions in plain text. The 9264.952.1GEL is the already fixed English variant of the ATEX stand-up station: it ships without any further language selection, which makes it the right choice for sites working in English.

Features of this order variant

  • Instruction panel permanently in English, no language choice needed when ordering
  • ATEX rating: footwear high limit fixed at 1 GΩ
  • Free standing layout with column, footplate and panel
  • Wrist strap test 750 kΩ to 35 MΩ, separate measurement of left and right shoe
  • Test voltage 50 V or 100 V, relay contact for the EPA access

Four operating modes

  • Simultaneous measurement of wrist strap and footwear in a single test
  • Wrist strap only, for operators seated at the workstation
  • Footwear only, for visitors without a wrist strap
  • HandsFree: if both shoes pass the series measurement, the internal relay switches and releases the access gate to the EPA

Applications

International sites and group plants working in English where an explosion relevant entrance also has to verify ESD personnel grounding.

Accessories and compatibility

Identical to 9264.952.1G: dual footplate 9264.965, turnstile 9266.100, recalibration 9264.955 and the resistance decade boxes 9264.980 and 9264.981 for in house checks.

Made in Italy by Iteco, with an ISO 9000 traceable calibration report.

Technical data

Test standardIEC 61340-5-1
Items testedWrist strap and footwear, left and right shoe measured separately
Test voltage50 V or 100 V, selectable
Wrist strap limitslow limit 750 kΩ / high limit 35 MΩ
Footwear low limit0 to 100 kΩ, selectable
Footwear high limit1 GΩ fixed, ATEX compliant version
Operating modes4 (wrist strap and footwear together, wrist strap only, footwear only, HandsFree)
Outputrelay contact for releasing access to the EPA
Power supplyinternal 9 V battery or external 9 V DC
Instrument dimensions156 x 110 x 34 mm
Instrument weight340 g
CalibrationISO 9000 traceable calibration report included
Mountingfree standing on a column support
Scope of deliveryWristlab-II instrument in ATEX version, footplate, yellow instruction panel in English, stand-up support, calibration report
Panel languageEnglish, fixed
OriginItaly
Weight1 kg
ManufacturerIteco
Manufacturer Nr.9264952.1GEL
GPSR manufacturer informationIteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it
Country of ManufactureItaly
Sales unitStück
ESD versionESD (antistatic)
NormDIN EN ISO 9000
CertificationATEX, IEC 61340-5-1
Operating voltage9 V
SeriesWristlab II