Resistance Meter Gigalab EVO 10 to 500 V, 1 kOhm to 1 TOhm - Iteco 9265063
-
This Item:
€614.57
-
ESD teraohmmeter portable with temperature and humidity measurement
€2,926.72
-
ESD Survey Kit in carrying case with instruments for EPA audits to IEC 61340-5-1 - Iteco 9265151
€4,604.81
Measuring resistance above one gigaohm means fighting interference and answering the question at which voltage the reading was taken. The Gigalab EVO settles both, it offers four selectable test voltages from 10 to 500 V and works with a shielded cable and shielded probe up to 1 teraohm.
Operating benefits
- Four test voltages of 10, 100, 250 and 500 V cover 1 kohm to 1 Tohm without a second instrument.
- The shielded measuring system suppresses interference that otherwise makes readings unsteady at high resistance values.
- Memory for 100 readings with resistance value, test voltage, humidity and temperature, so the conditions of each measurement stay documented.
- Built in humidity and temperature measurement from 1 to 95 percent relative humidity and -20 to +60 degrees Celsius.
- Graphic LCD with 128 x 64 pixels on 68 x 51 mm, switched between natural and exponential notation by one button.
- 650 g light at 243 x 130 x 60 mm and independent of the mains with 6 alkaline LR6 batteries.
Technical data
| Type | Gigalab EVO, multi voltage high resistance meter with batteries and case |
|---|---|
| Test voltage 10 V | 1 kohm to 50 Gohm, accuracy 5 percent plus 0.6 percent per Gohm |
| Test voltage 100 V | 100 kohm to 1 Tohm, accuracy 5 percent plus 0.06 percent per Gohm |
| Test voltage 250 V | 500 kohm to 1 Tohm, accuracy 5 percent plus 0.045 percent per Gohm |
| Test voltage 500 V | 1 Mohm to 1 Tohm, accuracy 5 percent plus 0.03 percent per Gohm |
| Measured quantities | point to point resistance, resistance to ground, surface resistance |
| Humidity measurement | 1 to 95 percent relative humidity, accuracy 2 percent |
| Temperature measurement | -20 to +60 degrees Celsius, accuracy 1 degree |
| Memory | 100 readings with resistance value, test voltage, humidity and temperature |
| Display | graphic LCD, 128 x 64 pixels, 68 x 51 mm |
| Reading format | switch between natural and exponential notation by button |
| Acoustic alarm | yes, programmable threshold |
| Measuring system | shielded cable and shielded probe to suppress electromagnetic interference |
| Power supply | 6 alkaline batteries LR6 1.5 V |
| Dimensions | 243 x 130 x 60 mm |
| Weight | 0.65 kg |
| Data interface | not fitted, see Gigalab EVO Plus 9265.066 |
| Scope of delivery | meter, batteries, case, traceable calibration report |
| Origin | Italy |
Typical applications
- Measurement of point to point resistance and resistance to ground of floors, mats and worktops to IEC 61340-5-1.
- Testing insulating and dissipative materials that call for 100 V or 500 V test voltage.
- Periodic EPA audits with a record taken from the internal memory.
- Judging results in relation to the humidity measured at the same moment.
Compatibility and scope of delivery
Suitable probes are the shielded probe 63 mm at 2.3 kg (Iteco 9265.065), the concentric ring probe 63/30 mm at 2.5 kg (Iteco 9265.070), the counter-electrode 150 x 150 mm for volume resistance (Iteco 9265.047) and the 25 cm T-handle with M5 thread for floor work (Iteco 9265.072). Together with the Walking Test EVO Iteco 9265.080 the meter forms the core of the ESD Survey Kit. With two probes and a case it is available as the set Iteco 9265.064.
Standards and origin
Point to point resistance, resistance to ground and surface resistance correspond to the quantities described in IEC 61340-5-1. A traceable calibration report is included, recalibration can be ordered as Iteco 9265.042. Made in Italy.
| Certification | IEC 61340-5-1 |
|---|---|
| ESD version | ESD (antistatic) |
| Manufacturer Nr. | 9265063 |
| Manufacturer | Iteco |
| Country of Manufacture | Italy |
| Weight | 0.650000 |
| Height | 243 |
| Width | 130 |
| Depth | 60 |
| Sales unit | Stück |
| GPSR manufacturer information | Iteco Trading S.r.l, Via Paisas 1, IT-10094 Giaveno (TO), www.iteco.it |
| Temperature range | -20-60 °C |
| Series | Gigalab EVO |
| Operating voltage | 9 V |























