Images are examples, some edited with AI. The technical data are authoritative. AI notice
Field meter verification kit in aluminium case
Complete verification set combining the field meter, a charge plate set and a volt meter set for the walking test in a sturdy aluminium case. It covers field measurement, ioniser verification to IEC 61340-5-1 and body voltage measurement in one package. Central equipment for recurring ESD audits in the protected area.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The Safeguard SFM PRO AKC brings the full range of precise ESD measurement systems together in a sturdy aluminium case with foam insert. The set combines the Safeguard field meter, the charge plate set (CPS) and a volt meter set (VMS) for the walking test, covering field measurement, ioniser verification and body voltage measurement.
The field meter works on the field mill principle: a star-shaped induction electrode interacts with a grounded rotating modulation impeller, and a ring electrode system protects the impeller and field plate. With the charge plate set it becomes a charge plate monitor for ionisation equipment; the decay time from +1,000 V to +100 V (or -1,000 V to -100 V) is timed by the built-in start-stop timer, with charging supplied by an external HV converter. The volt meter set extends the system into a walking test kit with voltage probe, hand electrode and accessories.
Key benefits
- Three measurement tasks in one case: field measurement, charge plate monitoring and walking test.
- Ioniser verification to IEC 61340-5-1 and EOS/ESD S3.1 via the CPS.
- Walking test for body voltage measurement and ESD control checks.
- Very high zero-point stability: no adjustment needed before each measurement.
- One-button operation with battery voltage monitoring and auto power-off.
Applications
- Recurring ESD audits and verifications in the EPA.
- Periodic ioniser testing (decay time and offset).
- Body voltage measurement via the walking test.
Standards and compliance
The charge plate set enables ioniser verification to DIN EN 61340-5-1 and EOS/ESD S3.1. The complete kit supports an ESD control programme to the IEC 61340 series.
Technical data
| Measuring method | induction (field mill principle) |
|---|---|
| E-field range | 0 to +/- 200 kV (distance mode), 0 to 1 MV/m (field strength mode) |
| Manual E-field ranges | +/- 20 kV/m, +/- 200 kV/m, +/- 1 MV/m |
| Decay time measurement (CPS) | +/- 1,000 V to +/- 100 V, built-in start-stop timer |
| Standard measuring distance | 2 cm |
| Calibration accuracy | under 5 % |
| Analogue output | +/- 1 V (Ri above 1 kOhm), E-field mode only |
| Display | two-line, 12-digit alphanumeric LCD |
| Power | 9 V NiMH battery, approx. 10 h operation |
| Weight | 0.1 kg |
| Manufacturer | Safeguard |
| Manufacturer Nr. | SFM PRO AKC |
| HS-Code | 90303900 |
| GPSR manufacturer information | KW-SG Elektrotechnik GmbH Industriestraße 11 AT-9601 Arnoldstein www.kwsg.at |
| Condition of article | New |
| Article authenticity | Original product |
| Sales unit | 1 Stück |
| ESD version | ESD (antistatic) |
| Norm | ESD S3.1 |
| Certification | IEC 61340, IEC 61340-5-1 |
Scope of delivery
- Safeguard field meter
- Charge plate set (plates, HV converter, stand)
- Volt meter set (voltage probe, hand probe, cable)
- 2x 9 V NiMH battery and plug charger
- Crocodile clip, coiled cable
- Sturdy aluminium case with foam insert
- Operating manual
Downloads
Accessories
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.