Field meter verification kit in aluminium case - Safeguard SFM PRO AKC
-
This Item:
€1,300.00Excl. 19% VAT , excl. Shipping Cost
-
ESD verification kit with case - Warmbier SRM 200
€957.27Excl. 19% VAT , excl. Shipping Cost
-
ESD high-impedance meter with digital display - Safeguard MegaGuard Pro
€282.14Excl. 19% VAT , excl. Shipping Cost
The Safeguard SFM PRO AKC verification kit provides the full range of precise ESD measuring systems in a rugged aluminium case. It combines the Safeguard electrostatic field meter, the Charge Plate Set (CPS) and a Volt Meter Set (VMS) for the walking test, covering field measurement, ionizer verification and body-voltage measurement.
The field meter works on the field-mill principle: a star-shaped induction electrode operates with a grounded rotating modulation vane; a ring-electrode system protects the vane and field plate. With the Charge Plate Set it becomes a charge-plate monitor for verifying air ionizers to DIN EN 61340-5-1 and EOS/ESD S3.1; the decay time from +1,000 V to +100 V or -1,000 V to -100 V is measured with an integrated start-stop timer, with charging via an external HV converter. The Volt Meter Set extends the system into a walking test kit comprising the MK voltage measuring head, a hand electrode and accessories for measuring body voltage.
Key benefits
- Three measurement tasks in one case: field measurement, charge-plate monitoring and walking test.
- Ionizer verification to IEC 61340-5-1 / EOS-ESD S3.1 via the CPS.
- Walking test for measuring body voltage and checking ESD protection.
- Rugged aluminium case with foam insert for safe transport.
- Very high zero-point stability: no calibration needed before each reading.
- Single-button operation and battery-voltage monitoring with automatic shut-off.
Technical specifications
| Measuring principle | Induction (field-mill) principle |
| Measuring range (E-field) | 0 to +/- 200 kV (distance mode), 0 to 1 MV/m (field-strength mode) |
| Manual E-field ranges | +/- 20 kV/m, +/- 200 kV/m, +/- 1 MV/m |
| Decay-time measurement (CPS) | +/- 1,000 V to +/- 100 V, integrated start-stop timer |
| Standard measuring distance | 2 cm |
| Calibration accuracy | < 5 % |
| Analog output | +/- 1 V (Ri > 1 kOhm), E-field mode only |
| Display | two-line, 12-digit alphanumeric LCD |
| Power supply | 9 V NiMH battery, approx. 10 h operation |
Applications
- Recurring ESD audits and verifications in the EPA.
- Periodic verification of ionizers (decay time and offset).
- Measurement of body voltage via the walking test.
Scope of delivery
- Safeguard electrostatic field meter (EFM)
- Rugged aluminium case with foam insert
- CPS set (plates, HV converter, stand)
- WT set (voltage measuring head, hand probe, cable)
- 2x 9 V NiMH battery
- Plug-in charger for 9 V battery
- Crocodile clip
- Coiled cable
- User manual
Standards and compliance
The Charge Plate Set enables ionizer verification to DIN EN 61340-5-1 and EOS/ESD S3.1. The complete kit supports an ESD control program to the IEC 61340 series. Fully standard-compliant charge-plate measurements require the larger CPM charge-plate monitor.
| Manufacturer Nr. | SFM PRO AKC |
|---|---|
| Manufacturer | Safeguard |
| Weight | 0.100000 |
| GPSR manufacturer information | KW-SG Elektrotechnik GmbH Industriestraße 11 AT-9601 Arnoldstein www.kwsg.at |
| Article authenticity | Original product |
| Condition of article | New |