Planning a Pass-Through Chamber - Which Type Fits?

A pass-through chamber (pass box) moves material into the cleanroom without a person crossing the barrier. This guide explains the three types - passive, active with interlock and HEPA-purged - along with sizing, interlock logic and cleaning as a compact alternative to a walk-in material airlock.

5 minStand: 2026-07Geprüft: Cleanroom specialists
View pass-through chambers
3 types
passive, active, HEPA
H14
HEPA filter, 99.995 %
electr.
both doors interlocked
14644-1
governing standard
Inhalt
  1. Purpose and benefit
  2. The three types
  3. Planning and install
  4. Cleaning and testing
  5. Frequently asked questions

What does a pass-through chamber do?

A pass-through chamber is a transfer hatch with two opposing doors that moves material between two clean zones without anyone crossing the cleanroom barrier. It cuts personnel traffic - the largest particle source in any cleanroom - and takes far less floor space than a walk-in material airlock.

The core principle is the interlock: only one of the two doors can open at a time. This preserves the pressure gradient between zones and prevents a direct air short-circuit from the dirty side to the clean side.

Rule of thumb: anything that does not have to be carried by a person goes through the pass box. That relieves the personnel airlock and lowers the particle load inside the cleanroom.
Cleanroom classes

How to match ISO classes to particle limits correctly.

Read the guide

Passive, active or HEPA-purged?

There are three basic designs that differ in airflow and interlocking. The choice depends on the cleanroom class, the contamination risk of the material and the required throughput.

The passive box has no own air supply and simply transfers goods between two zones of equal cleanliness. The active version adds electrical locking with a traffic-light indicator and an optional dwell timer. The HEPA-purged box floods the item with filtered air to shed adhering particles before the inner door is released.

  • Passive: low cost, low maintenance, ideal for consumables in lower ISO classes.
  • Active interlocked: safe door logic, status light and logging for regulated processes.
  • HEPA-purged: active particle reduction, required when entering ISO 6 or cleaner.
  • Stainless steel 1.4301/1.4404 (304/316L) as the standard for pharma and microelectronics.

What matters when planning and installing?

Three figures are fixed before ordering: the clear chamber opening, the wall thickness and the interlock logic. The opening must fit the largest item transferred regularly - typical inside dimensions run from 400 x 400 x 400 mm to 600 x 600 x 600 mm.

Place door handles, status lights and the HEPA service hatch on the correct cleanroom side. The filter must be changeable from the less clean side without opening the clean zone.
  • Check pressure cascade: the chamber must not short-circuit the pressure gradient between zones.
  • Provide an emergency release in case of power failure (personnel and material safety).
  • For HEPA purge, add the purge lead time into the process cycle.
Personnel airlock

How to size gowning and air showers for personnel entry.

Read the guide

How is the pass box cleaned and tested?

Smooth stainless surfaces with rounded internal corners wipe-disinfect without residue. Clean from the clean side toward the less clean side using cleanroom wipes and approved disinfectants.

On HEPA-purged boxes the H14 filter is integrity-tested periodically and the airflow is verified. Depending on load, a filter change is typically due every 2 to 4 years.
  • Test the interlock regularly: both doors must never open at the same time.
  • Inspect seals and door catches for wear.
  • Leak-test the HEPA filter per ISO 14644 and document the result.

Frequently asked questions

When do I need a HEPA-purged rather than a passive box?

As soon as material moves from a less clean into a cleaner zone (say ISO 6 or cleaner), an active HEPA purge makes sense because it sheds adhering particles before release. If both sides share the same cleanliness, a passive box is usually enough.

Why can only one door open at a time?

The interlock keeps the pressure gradient between zones and prevents a direct air short-circuit. If both doors opened together, unfiltered air could flow into the cleanroom.

Which inside size should I choose?

Size the clear opening to the largest item transferred regularly and add 20 to 30 % reserve for handling. Common sizes range from 400 x 400 x 400 mm to 600 x 600 x 600 mm.

Passive or active interlocked?

Passive boxes with a mechanical interlock are cheap and low maintenance. Active, electrically interlocked models with a status light and logging suit higher throughput and regulated, documented processes.

Looking for a pass-through chamber?

We supply passive, active interlocked and HEPA-purged stainless pass boxes - sized to your wall thickness, cleanroom class and throughput.

Safe door logic

Mechanical or electrical interlock with emergency release.

HEPA H14

Optional purge at 99.995 % capture efficiency.

Standard-based

Designed to ISO 14644-1.

Expert advice

Cleanroom specialists help with size and type.